{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"AF38-30-22-11","brand":"ABB","brandSlug":"abb","productSlug":"AF38-30-22-11","canonicalUrl":"https://aoctrl.com/abb/AF38-30-22-11","factsUrl":"https://aoctrl.com/api/mcp/products/AF38-30-22-11","rawCanonicalId":null},"summary":{"shortDescription":"ABB AF38-30-22-11, 3-pole contactor, 32.2 A rated current, 20-60 V coil.","salesMarkdown":"The ABB AF38-30-22-11 is a 3-pole contactor rated at 32.2 A with a 20-60 V control coil. The coil range covers 20 through 60 V AC/DC, which gives you flexibility if your control voltage isn't nailed down or you're working across multiple panel designs. ## What the ratings actually mean for fit The 32.2 A rating is the AC-3 duty current for motor switching — that's the number that decides whether this contactor handles your load under starting and running conditions. It's not a resistive-heating rating; it's the motor-rated current, so it directly governs whether the contacts survive repetitive inductive switching. The 20-60 V coil span means the pickup and dropout voltages sit within that band, which matters if your control transformer sags under load or you're running a long DC control loop.","metaTitle":"ABB AF38-30-22-11 Contactor, 3-Pole 32.2A, 20-60V Coil","metaDescription":"ABB AF38-30-22-11 3-pole contactor rated 32.2A with 20-60V coil. Currently in active production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"title":"AF38-30-22-11","description":"ABB AF38-30-22-11 CTR,3P,32.2A,20-6|ABB AF38302211 CTR 3P 32.2A 2","lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d7848fe13def3828895aaf2377f6ca3.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the rated current and coil voltage for the AF38-30-22-11?","answer":"It's a 3-pole contactor rated at 32.2 A with a 20-60 V control coil. The 32.2 A figure is the AC-3 motor-switching current, which is the spec that determines motor load fit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/AF38-30-22-11","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/AF38-30-22-11 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}