{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"AJ65SBTB1-32DT","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"AJ65SBTB1-32DT","canonicalUrl":"https://aoctrl.com/mitsubishi/AJ65SBTB1-32DT","factsUrl":"https://aoctrl.com/api/mcp/products/AJ65SBTB1-32DT","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi AJ65SBTB1-32DT CC-Link Remote I/O Station, 16-point DC Input (plus common), 16-point Transistor Output (sink type), 24 VDC, 0.5 A per point.","salesMarkdown":"The Mitsubishi AJ65SBTB1-32DT is a CC-Link remote I/O station delivering 16 DC inputs (sink type, 24 VDC, 7 mA typical) and 16 transistor outputs (sink type, 24 VDC, 0.5 A per point, 3.6 A per common bus). Input isolation is photocoupler; output side adds overload, overvoltage, and overheat protection — a step up from basic fuse-only modules. Power draw: 60 mA at 24 VDC with all points ON, so the station adds roughly 1.5 W to the 24V rail. The NZ2EX2B1-16D is a 16-point DC input module for the MELSEC iQ‑F series — same function class but no outputs, no CC‑Link interface, and a different physical footprint (slim 12mm slice vs 179mm wide standalone block). It is not a drop‑in second‑source. For a pure input expansion on an iQ‑F base it is the modern equivalent, but the AJ65SBTB1-32DT remains the correct fit for CC‑Link networks needing combined I/O in a single addressed station. Panel‑mount only: 179 mm wide × 40 mm deep, rated IP2X. Pollution degree 2, overvoltage category II. Input supply tolerates 19.2–26.4 VDC (ripple ≤5%), so it rides through weak 24 V bus conditions. Output common is 32 points per common on a trapezoid terminal block — plan wire routing to keep the 3.6 A common limit. Surge suppression via zener diode on outputs. No corrosive gas environment specified; storage at 10–90% RH non‑condensing.","metaTitle":"Mitsubishi AJ65SBTB1-32DT CC-Link Remote I/O, 16 In/16 Out","metaDescription":"AJ65SBTB1-32DT CC-Link remote I/O station: 16 DC inputs (sink) + 16 transistor outputs (sink). 0.5 A/point, 24 VDC, mature lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Digital Output Modules"],"specifications":{"Mass":"0.25 Kg","Current":"60 mA or less (24 VDC, all points ON)","Depth (D)":"40 mm","Width (W)":"179 mm","ON → OFF":"1.5 ms or less (resistance load)","Input format":"DC input (plus common type)","Manufacturer":"Mitsubishi Electric","Station type":"Remote I / O station","Common method":"32 points 1 common (terminal trapezoid 1 wire type)","Output format":"Transistor output (sink type)","Use elevation":"0 to 2000 m","Use atmosphere":"No corrosive gas","Shipping Weight":"1.3 Kg","lifecycle_stage":"mature","Input resistance":"About 3.3 kΩ","Pollution degree":"2 or less","Protection grade":"IP2X","Surge suppressor":"Zener diode","Impact resistance":"Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)","Withstand voltage":"Between DC external terminal and ground: AC 500 V for 1 minute","Rated load voltage":"DC 24V","Estimated Lead Time":"Usually ships in 1 - 10 working days.","Protection function":"Overload protection function, overvoltage protection function, overheat protection function","Rated input current":"About 7 mA","Rated input voltage":"DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)","Maximum load current":"0.5 A / 1 point, 3.6 A / 1 common","Installation location":"In the control panel","Insulation resistance":"DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MΩ or more","Over voltage category":"II or less","Input isolation method":"Photocoupler isolation","Leakage current at OFF":"0.25 mA or less","Maximum inrush current":"1.0 A less than 10 ms","Number of input points":"16 points","Number of output points":"16 points","ON voltage / ON current":"14 V or more / 3.5 mA or more","Output isolation method":"Photocoupler isolation","Used load voltage range":"DC 19.2 to 26.4 V (ripple ratio within 5%)","Storage ambient humidity":"10 to 90% RH, non condensing","OFF voltage / OFF current":"6 V or less / 1.7 mA or less","Unit power supply Voltage":"DC 20.4 to 26.4 V (ripple ratio within 5%)","Ambient operating humidity":"10 to 90% RH, non condensing","Number of occupied stations":"1 station","Storage ambient temperature":"-20 to 75 ° C","Operating ambient temperature":"0 to 55 ° C","External dimensions Height (H)":"50 mm","Input response time OFF → ON":"1.5 ms or less (24 VDC)","Maximum voltage drop during ON":"DC 0.3 V or less (TYP.) 0.5 A, DC 0.6 V or less (MAX.) 0.5 A","Output response time OFF → ON":"0.5ms or less","External wiring connection method":"Communication part, unit power supply part: 7 points 2 piece terminal block (M3 screw) I / O power supply part, input / output part: 34 points Direct mounting terminal block (M3 screw)","When there is continuous vibration":"Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2","Maximum number of simultaneous input points":"100%","Output section External power supply Voltage":"DC 19.2 to 26.4 V (ripple ratio within 5%)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$257.00 – $359.70","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/AJ65SBTB1-32DT/alternatives.json"},"ai":{"faq":[{"question":"Can the NZ2EX2B1-16D replace the AJ65SBTB1-32DT?","answer":"No. The NZ2EX2B1-16D is a 16‑point input module for the MELSEC iQ‑F series — it has no outputs and no CC‑Link remote station interface. It is not electrically or mechanically interchangeable."},{"question":"What is the mass of the AJ65SBTB1-32DT?","answer":"The unit mass is 0.25 kg. Shipping weight is 1.3 kg due to packaging."},{"question":"What is the current consumption?","answer":"60 mA or less at 24 VDC with all points ON, plus a typical 7 mA per input channel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/AJ65SBTB1-32DT","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/AJ65SBTB1-32DT when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}