{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"AJ65SBTB1-32DT3","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"AJ65SBTB1-32DT3","canonicalUrl":"https://aoctrl.com/mitsubishi/AJ65SBTB1-32DT3","factsUrl":"https://aoctrl.com/api/mcp/products/AJ65SBTB1-32DT3","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi Electric AJ65SBTB1-32DT3 CC-Link small type remote I/O unit, DC input / transistor output, 16 input points, 16 output points, 24 VDC, 0.5 A per point, terminal block type.","salesMarkdown":"## CC-Link remote I/O station with 16 mixed points The AJ65SBTB1-32DT3 is a CC-Link remote I/O station combining 16 DC input points (sink/source, plus common) and 16 transistor output points (sink type) in a single terminal-block unit. Rated for 24 VDC field power with an allowable range of 19.2 to 26.4 V, each output point handles up to 0.5 A with a common limit of 3.6 A — sized for solenoid valves, indicator lamps, and small contactor coils on a shared common. Inputs present about 5 mA at 24 V through a 4.7 kΩ resistor, with an ON threshold above 15 V and OFF below 3 V, so it interfaces cleanly with standard 24 VDC proximity and limit switches without external signal conditioning. ## Panel fit and bus power budget The unit draws 60 mA or less from the 24 VDC bus with all points ON, so the bus supply needs to budget only that plus the field load current through the commons. IP2X protection and pollution degree 2 rating mean it is intended for enclosed cabinet installation — not for direct washdown or outdoor exposure. ## Switching speed and surge protection Output ON/OFF response is 1.5 ms or less into a resistive load, fast enough for most discrete sequencing but not for high-speed counter or servo index pulses — those need a dedicated high-speed output module. Each output includes a Zener diode surge suppressor, so inductive loads like relays and small contactors do not require external flyback diodes across the output terminals. Leakage current at OFF is 0.1 mA or less, which prevents phantom energisation of sensitive loads like PLC input modules sharing the same 24 VDC rail.","metaTitle":"Mitsubishi AJ65SBTB1-32DT3 CC-Link Remote I/O, 16/16 Points","metaDescription":"Mitsubishi AJ65SBTB1-32DT3 CC-Link remote I/O unit, 16 DC inputs + 16 transistor outputs, 24 VDC, 0.5 A/point. Mature lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Digital Output Modules"],"specifications":{"Mass":"0.25 Kg","title":"AJ65SBTB1-32DT3","Current":"60 mA or less (24 VDC, all points ON)","ON ? OFF":"1.5 ms or less (resistance load)","Depth (D)":"40 mm","Width (W)":"179 mm","Product no":"AJ65SBTB1-32DT3","description":"CC-Link small type remote I / O unit (DC input / transistor output, terminal block)","Input format":"DC input (plus common type)","Product type":"CC-Link small type remote I / O unit (DC input / transistor output, terminal block) AJ65SBTB 1-32DT3","Station type":"Remote I / O station","Common method":"32 points 1 common (terminal trapezoid 1 wire type)","Output format":"Transistor output (sink type)","Use elevation":"0 to 2000 m","Use atmosphere":"No corrosive gas","Shipping Weight":"1.3 Kg","lifecycle_stage":"mature","Input resistance":"About 4.7 kO","Pollution degree":"2 or less","Protection grade":"IP2X","Surge suppressor":"Zener diode","Impact resistance":"Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)","Withstand voltage":"Between DC external terminal and ground: AC 500 V for 1 minute","Rated load voltage":"DC 24V","Estimated Lead Time":"Usually ships in 1 - 10 working days.","Rated input current":"About 5 mA","Rated input voltage":"DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)","Maximum load current":"0.5 A / 1 point, 3.6 A / 1 common","Installation location":"In the control panel","Insulation resistance":"DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 MO or more","Over voltage category":"II or less","Input isolation method":"Photocoupler isolation","Leakage current at OFF":"0.1 mA or less","Maximum inrush current":"1.0 A less than 10 ms","Number of input points":"16 points","Number of output points":"16 points","ON voltage / ON current":"15 V or more / 3 mA or more","Output isolation method":"Photocoupler isolation","Used load voltage range":"DC 19.2 to 26.4 V (ripple ratio within 5%)","Storage ambient humidity":"10 to 90% RH, non condensing","OFF voltage / OFF current":"3 V or less / 0.5 mA or less","Unit power supply Voltage":"DC 20.4 to 26.4 V (ripple ratio within 5%)","Ambient operating humidity":"10 to 90% RH, non condensing","Number of occupied stations":"1 station","Storage ambient temperature":"-20 to 75 ° C","Input response time OFF ? ON":"0.2 ms or less (24 VDC)","Operating ambient temperature":"0 to 55 ° C","Output response time OFF ? ON":"0.5ms or less","External dimensions Height (H)":"50 mm","Maximum voltage drop during ON":"DC 0.3 V or less (TYP.) 0.5 A, DC 0.6 V or less (MAX.) 0.5 A","External wiring connection method":"Communication part, unit power supply part: 7 points 2 piece terminal block (M3 screw) I / O power supply part, input / output part: 34 points Direct mounting terminal block (M3 screw)","When there is continuous vibration":"Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2","Maximum number of simultaneous input points":"100%","Output section External power supply Voltage":"DC 19.2 to 26.4 V (ripple ratio within 5%)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$152.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c447376ec3b9cd93bfe0bcf2e4f26374.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the AJ65SBTB1-32DT3 used for?","answer":"It is a CC-Link remote I/O station that provides 16 DC inputs and 16 transistor-sink outputs in a single terminal-block unit, typically used in Mitsubishi CC-Link networks for distributed control of sensors and actuators within a control panel."},{"question":"How do I get pricing and availability for the AJ65SBTB1-32DT3?","answer":"Submit an RFQ through this listing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/AJ65SBTB1-32DT3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/AJ65SBTB1-32DT3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}