{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM1A0C16N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM1A0C16N4","canonicalUrl":"https://aoctrl.com/schneider/APM1A0C16N4","factsUrl":"https://aoctrl.com/api/mcp/products/APM1A0C16N4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular power module, APM1A0C16N4, 160...132 kW, 380...480 V, 302 A normal duty IP00.","salesMarkdown":"## Altivar Process Modular power module for 160 kW drives The APM1A0C16N4 is a 160 kW (normal duty) / 132 kW (heavy duty) power module in the Altivar Process Modular range, rated for 380...480 VAC three-phase input. It delivers 302 A continuous at 2.5 kHz for normal duty and 250 A for heavy duty, matching a 250 hp motor at 480 V normal duty or 200 hp heavy duty. This is the power stage only — the kit includes the mains unit, fan supply, and fan relay, but you'll need the matching control module and cabinet integration. Physical footprint: 1705 mm height, 230 mm wide, 510 mm deep — that's a full-height cabinet mount, not a wall-mount. IP00 as shipped; cabinet integration can achieve IP21 or IP54 per IEC 61800‑5‑1.","metaTitle":"Schneider APM1A0C16N4 Altivar Process Power Module, 250 HP","metaDescription":"Obsolete Altivar Process Modular power module, 160 kW/250 HP normal duty, 302 A continuous, 380-480 V. Source to order via RFQ for last-time-buy.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"510 mm","Width":"230 mm","Height":"1705 mm","Marking":"CE","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 300 m conforming to IEC 61800-3 category C3","Maximum THDI":"<48 % from 80...100 % of load","Mounting mode":"Cabinet mount","Apparent power":"223 kVA at 480 V normal duty 181 kVA at 480 V heavy duty","Motor power hp":"250 hp at 480 V normal duty 200 hp at 480 V heavy duty","Motor power kW":"160 kW at 380...480 V (normal duty) 132 kW at 380...480 V (heavy duty)","Kit composition":"1 power module 1 mains unit 1 power supply for fan 48 V 1 relay for fan 3 fuse holder 2 brackets with nuts screws and washers for fuse","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"7 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"APM","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Operating position":"Vertical +/- 10 degree","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Prospective line Isc":"50 kA","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP21 (for cabinet integration) conforming to IEC 61800-5-1 IP54 (for cabinet integration) conforming to IEC 61800-5-1","Network number of phases":"3 phases","Continuous output current":"302 A at 2.5 kHz for normal duty 250 A at 2.5 kHz for heavy duty","Product or component type":"Power module","[Us] rated supply voltage":"380...480 V - 10...10 %","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Permissible temporary current boost":"1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty)","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/APM1A0C16N4/standard-power-module-altivar-process-modular-110-160kw-380480v-ip00/","alternativesUrl":"https://aoctrl.com/api/mcp/products/APM1A0C16N4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM1A0C16N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM1A0C16N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}