{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM1B0C20Y6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM1B0C20Y6","canonicalUrl":"https://aoctrl.com/schneider/APM1B0C20Y6","factsUrl":"https://aoctrl.com/api/mcp/products/APM1B0C20Y6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular power module, APM1B0C20Y6, 200 kW normal duty at 500...690 V, IP00, cabinet mount.","salesMarkdown":"This is the APM1B0C20Y6, an Altivar Process Modular power module from Schneider Electric. It's the line-side / regenerative section of a modular drive system, rated for 200 kW normal duty (160 kW heavy duty) at 500...690 V three-phase. The continuous output current is 215 A at 2.5 kHz for normal duty, 175 A for heavy duty. It ships as a kit: power module, three fuse holders, and mounting hardware. The 215 A continuous output at 2.5 kHz is the normal-duty figure — that's your sustained motor current for a 200 kW asynchronous or synchronous motor on a 500...690 V line. Heavy duty drops to 175 A at 2.5 kHz, which covers 160 kW for higher starting torque or cyclic loads. The switching frequency is adjustable 2.5...4.9 kHz with derating; if you need quieter motor operation at 4.9 kHz, expect a lower continuous current. The integrated EMC filter meets IEC 61800-3 category C3 with 300 m of motor cable — that's second-environment (industrial) compliance. For first-environment (residential) you'd need an external filter. Total harmonic distortion of input current (THDI) is under 5% at full load, which keeps line pollution low without a separate line reactor in most cases. Cabinet mount only, IP00 as delivered. Dimensions are 1722 mm high, 450 mm wide, 508 mm deep. This module drives asynchronous or synchronous motors in pump, fan, conveyor, or regenerative applications — any process line where you need a modular, serviceable drive architecture. The regenerative capability means it can return energy to the line during deceleration, which cuts braking resistor costs and improves system efficiency. ## Standards and environment Carries CE marking and complies with UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Pollution degree 2. Rated for chemical resistance class 3C3 and dust class 3S3 per IEC 60721-3-3. EMC immunity includes level 3 for ESD, radiated RF, and conducted RF, level 4 for fast transients and surges. Operating temperature is -10 to 40 °C without derating, up to 50 °C with derating. Altitude up to 4800 m with current derating above 1000 m.","metaTitle":"Schneider APM1B0C20Y6 Altivar Process Modular Power Module,","metaDescription":"Active Altivar Process Modular power module, 200 kW normal duty at 500-690 V, 215 A continuous, integrated EMC filter C3, THDI <5%. Sourced to order, RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Depth":"508 mm","Width":"450 mm","title":"APM1B0C20Y6","Height":"1722 mm","Marking":"CE","Standards":"UL 61800-5-1 IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 300 m conforming to IEC 61800-3 category C3","description":"LH/regen power module, Altivar Process Modular, 110...200kW, 500...690V, IP00","Maximum THDI":"<5 % full load","Mounting mode":"Cabinet mount","Apparent power":"219 kVA at 500...690 V normal duty 177 kVA at 500...690 V heavy duty 145 kVA at 380...480 V normal duty regenerative mode 119 kVA at 380...480 V heavy duty regenerative mode","Motor power hp":"200 hp at 500...690 V normal duty 175 hp at 500...690 V heavy duty","Motor power kW":"200 kW at 500...690 V (normal duty) 160 kW at 500...690 V (heavy duty)","Kit composition":"1 power module 3 fuse holder screws and washers for fuse","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"APM","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Operating position":"Vertical integrated in cabinet","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz with derating factor 2.5...4.9 kHz adjustable","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Prospective line Isc":"50 kA","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP21 (for cabinet integration) conforming to IEC 61800-5-1 IP54 (for cabinet integration) conforming to IEC 61800-5-1","Network number of phases":"3 phases","Continuous output current":"215 A at 2.5 kHz for normal duty 175 A at 2.5 kHz for heavy duty","Product or component type":"Power module","[Us] rated supply voltage":"500...690 V - 10...10 %","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Permissible temporary current boost":"1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty)","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/APM1B0C20Y6/lh-regen-power-module-altivar-process-modular-110200kw-500690v-ip00/"},"ai":{"faq":[{"question":"What are the key ratings for the APM1B0C20Y6?","answer":"Motor power 200 kW normal duty / 160 kW heavy duty at 500...690 V, continuous output current 215 A normal duty / 175 A heavy duty at 2.5 kHz switching frequency, with integrated EMC filter C3 and THDI <5% at full load."},{"question":"What is the physical size of the APM1B0C20Y6?","answer":"Height 1722 mm, width 450 mm, depth 508 mm. Cabinet mount, IP00 as delivered."},{"question":"What compliance documentation does this module carry?","answer":"CE marked, compliant with UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM1B0C20Y6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM1B0C20Y6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}