{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM1L0CCM230","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM1L0CCM230","canonicalUrl":"https://aoctrl.com/schneider/APM1L0CCM230","factsUrl":"https://aoctrl.com/api/mcp/products/APM1L0CCM230","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular APM1L0CCM230, cabinet cooling module, 230V AC, liquid cooled, IP00/IP21/IP66, cabinet mount.","salesMarkdown":"The Schneider Electric APM1L0CCM230 is a cabinet cooling module in the Altivar Process Modular range, designed as a power module for liquid-cooled drive cabinets. The module carries IP00 as a bare component, but when integrated into a cabinet it achieves IP21 or IP66 depending on the enclosure design. UL Type 1 and Type 12 ratings per UL 61800-5-1 apply for cabinet integration, so it is accepted in North American industrial panels where those enclosure types are specified. It is compliant with UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1 — covering safety, EMC, environmental classification, and functional safety for variable-speed drive systems. ## Environmental and installation constraints The module is rated for operating ambient temperatures from -10 °C to 40 °C without derating, and up to 50 °C with derating. Coolant temperature for operation must be between 5 °C and 40 °C. Altitude rating goes to 4800 m but with current derating above 1000 m — a standard requirement for drive system components. Pollution degree 2 per IEC 61800-5-1 applies, meaning only non-conductive pollution is expected, which is typical for controlled industrial environments. Vibration resistance is 1.5 mm peak-to-peak from 2 to 13 Hz and 0.5 gn from 13 to 200 Hz per IEC 60068-2-6. Shock resistance is 4 gn for 11 ms per IEC 60068-2-27. The module must be mounted vertically in a cabinet. Relative humidity tolerance is 5 to 95% without condensation per IEC 60068-2-3. Chemical pollution resistance class 3C3 and dust pollution resistance class 3S3 per IEC 60721-3-3 are specified, so the module can handle mildly corrosive atmospheres and moderate dust levels typical of process industries. ## EMC and electrical characteristics Electromagnetic compatibility is covered with immunity test levels: electrostatic discharge level 3, radiated RF level 3, fast transient burst level 4, surge 1.2/50 µs – 8/20 µs level 3, and conducted RF level 3 per the IEC 61000-4-x series. This means the module is hardened for industrial electrical environments with moderate to high interference. Insulation resistance is greater than 1 MΩ at 500 V DC for 1 minute to earth — a standard check for drive power modules. Dimensions are 429 mm deep, 254 mm wide, and 417 mm high.","metaTitle":"Schneider Electric APM1L0CCM230 Altivar Process Modular Cabi","metaDescription":"APM1L0CCM230 cabinet cooling module for Altivar Process Modular. 230V AC, liquid cooled, IP00/IP21/IP66, UL 61800-5-1. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Depth":"429 mm","Width":"254 mm","Height":"417 mm","Marking":"CE","Standards":"UL 61800-5-1 IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","Mounting mode":"Cabinet mount","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Operating position":"Vertical integrated in cabinet","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP21 (for cabinet integration) conforming to IEC 61800-5-1 IP66 (for cabinet integration) conforming to IEC 61800-5-1","Network number of phases":"1 phase","Product or component type":"Power module","[Us] rated supply voltage":"230 V","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Coolant temperature for operation":"5...40 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/APM1L0CCM230/cabinet-cooling-module-altivar-process-modular-230v-ac-liquid-cooled/","alternativesUrl":"https://aoctrl.com/api/mcp/products/APM1L0CCM230/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the APM1L0CCM230?","answer":"It is a 230 V single-phase cabinet cooling module for the Altivar Process Modular range, liquid cooled, with IP00/IP21/IP66 protection and UL Type 1/Type 12 enclosure ratings. It operates from -10 °C to 40 °C (derated to 50 °C) and up to 4800 m altitude with derating above 1000 m."},{"question":"What compliance documentation does Schneider provide for this module?","answer":"The module carries CE marking and complies with UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Standard documentation includes the EU Declaration of Conformity and UL recognition file."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM1L0CCM230","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM1L0CCM230 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}