{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM1L0LCMY6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM1L0LCMY6","canonicalUrl":"https://aoctrl.com/schneider/APM1L0LCMY6","factsUrl":"https://aoctrl.com/api/mcp/products/APM1L0LCMY6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular line choke module, APM1L0LCMY6, 500...690 V, liquid-cooled, with integrated EMC filter.","salesMarkdown":"The Schneider Electric APM1L0LCMY6 is a line choke module in the Altivar Process Modular range, designed to sit between the supply and the drive power stage. It handles 500...690 V three-phase input, with the supply frequency held at 50...60 Hz ±5%. The module is liquid-cooled, which means it rejects heat to a coolant loop rather than relying on cabinet airflow — a key distinction for sealed or high-density enclosures where traditional fan cooling is impractical. The voltage range is 500...690 V -10...10 %. It is a three-phase module with an integrated EMC filter rated to IEC 61800-3 category C3. Physical mounting is cabinet-mount only. The module measures 1124 mm high × 246 mm wide × 392 mm deep, so it occupies a full-height compartment in a multi-drive cabinet. The IP00 base rating means it is not touch-safe on its own; it relies on the cabinet enclosure for the IP21 or IP66 rating stated for cabinet integration. UL Type 1 and Type 12 ratings are available once installed, matching typical North American panel requirements. Operating temperature is -10 to 40 °C without derating, and up to 50 °C with a derating factor. Altitude derating starts above 1000 m, with operation possible up to 4800 m. The pollution degree is 2, which is standard for controlled environments — no special coating needed for most industrial atmospheres, though the chemical and dust resistance class 3C3 / 3S3 suggests it can tolerate moderate industrial contaminants. APM1L0LCMY6 is an active, current-production part. That means it is available through the standard Schneider distribution network, and the BOM line can be specified without last-time-buy risk. The liquid-cooled design limits direct drop-in alternatives within the Altivar Process Modular family; if the cabinet is plumbed for liquid cooling, this is the intended line choke for that architecture.","metaTitle":"Schneider APM1L0LCMY6 Altivar Process Modular line choke, 50","metaDescription":"Active line choke module for Altivar Process Modular drives. 500-690V 3-phase, liquid-cooled, integrated C3 EMC filter. UL/IEC compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Depth":"392 mm","Width":"246 mm","Height":"1124 mm","Marking":"CE","Standards":"UL 61800-5-1 IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated conforming to IEC 61800-3 category C3","Mounting mode":"Cabinet mount","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Operating position":"Vertical integrated in cabinet","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP21 (for cabinet integration) conforming to IEC 61800-5-1 IP66 (for cabinet integration) conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Power module","[Us] rated supply voltage":"500...690 V - 10...10 %","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/APM1L0LCMY6/line-choke-module-altivar-process-modular-500690v-liquid-cooled/","alternativesUrl":"https://aoctrl.com/api/mcp/products/APM1L0LCMY6/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of the APM1L0LCMY6?","answer":"The module is 1124 mm high, 246 mm wide, and 392 mm deep. It is a cabinet-mount unit, not a panel-mount or DIN-rail device."},{"question":"What compliance documentation is available for the APM1L0LCMY6?","answer":"The module is CE marked and complies with UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Standard Schneider declaration of conformity and UL recognition documentation should be available."},{"question":"What voltage and phase configuration does the APM1L0LCMY6 support?","answer":"It is a three-phase module rated for 500...690 V -10...10 %, with a supply frequency of 50...60 Hz ±5%."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM1L0LCMY6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM1L0LCMY6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}