{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM1L0LPMY6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM1L0LPMY6","canonicalUrl":"https://aoctrl.com/schneider/APM1L0LPMY6","factsUrl":"https://aoctrl.com/api/mcp/products/APM1L0LPMY6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular APM1L0LPMY6, line paralleling power module, 500...690 V, liquid cooled, cabinet mount.","salesMarkdown":"The Schneider Electric APM1L0LPMY6 is a line paralleling power module in the Altivar Process Modular range, designed to parallel multiple drive modules for higher current output or redundancy in liquid-cooled systems. It operates on a 500...690 V three-phase supply at 50/60 Hz, with a ±10 % tolerance on voltage and ±5 % on frequency. Rated IP00 on the module itself, but when integrated into a suitable cabinet it can achieve IP21 or IP66 per IEC 61800-5-1. UL Type 1 or Type 12 enclosure ratings are also attainable with proper cabinet integration per UL 61800-5-1. The module complies with a broad set of standards: UL 61800-5-1, IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic limits), IEC 60721-3 (environmental), IEC 61508 (functional safety), and IEC 13849-1 (machine safety). It carries CE marking and is rated for pollution degree 2 environments per IEC 61800-5-1. ## Installation and environmental constraints Cabinet-mount only, vertical operating position. Ambient temperature range is -10 to 40 °C without derating, and 40 to 50 °C with derating. Storage temperature spans -40 to 70 °C. Relative humidity 5 to 95 % non-condensing per IEC 60068-2-3. Altitude rating is ≤ 4800 m with current derating above 1000 m — a standard curve for drive power modules. Shock resistance is 4 gn for 11 ms per IEC 60068-2-27; vibration resistance is 1.5 mm peak-to-peak at 2-13 Hz and 0.5 gn at 13-200 Hz per IEC 60068-2-6. Chemical pollution resistance class 3C3 and dust pollution resistance class 3S3 per IEC 60721-3-3, meaning it withstands harsh industrial atmospheres with moderate chemical exposure and fine dust — provided the cabinet maintains the required IP rating. ## EMC and electrical characteristics EMC immunity is tested to level 3 for electrostatic discharge (IEC 61000-4-2), radiated RF (IEC 61000-4-3), and conducted RF (IEC 61000-4-6); level 4 for electrical fast transients (IEC 61000-4-4); and level 3 for surge (1.2/50 µs – 8/20 µs per IEC 61000-4-5). Insulation resistance exceeds 1 MΩ at 500 V DC for one minute to earth.","metaTitle":"Schneider Electric APM1L0LPMY6 Altivar Process Modular Power","metaDescription":"Schneider Electric APM1L0LPMY6 line paralleling power module for Altivar Process Modular drives. Rated 500-690 VAC, liquid-cooled, cabinet mount. Active production. UL, CE, IEC sta","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Depth":"350 mm","Width":"230 mm","Height":"348 mm","Marking":"CE","Standards":"UL 61800-5-1 IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","Mounting mode":"Cabinet mount","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Operating position":"Vertical integrated in cabinet","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP21 (for cabinet integration) conforming to IEC 61800-5-1 IP66 (for cabinet integration) conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Power module","[Us] rated supply voltage":"500...690 V - 10...10 %","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/APM1L0LPMY6/line-paralleling-module-altivar-process-modular-500690v-liquid-cooled/","alternativesUrl":"https://aoctrl.com/api/mcp/products/APM1L0LPMY6/alternatives.json"},"ai":{"faq":[{"question":"What are the key electrical ratings for the APM1L0LPMY6?","answer":"It is a three-phase line paralleling power module rated 500...690 VAC, 50/60 Hz, liquid-cooled. The exact current rating depends on the paralleling configuration and derating factors."},{"question":"What enclosure protection does the APM1L0LPMY6 offer?","answer":"The module itself is IP00. With proper cabinet integration it can achieve IP21 or IP66 per IEC 61800-5-1, and UL Type 1 or Type 12 per UL 61800-5-1."},{"question":"What compliance documentation is available for the APM1L0LPMY6?","answer":"The module is CE marked and complies with UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. RoHS and REACH declarations are standard for Schneider Electric Altivar products."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM1L0LPMY6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM1L0LPMY6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}