{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM1L0MPMN4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM1L0MPMN4","canonicalUrl":"https://aoctrl.com/schneider/APM1L0MPMN4","factsUrl":"https://aoctrl.com/api/mcp/products/APM1L0MPMN4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular APM1L0MPMN4 power module, 380...480 V, liquid cooled, cabinet mount.","salesMarkdown":"The Schneider Electric APM1L0MPMN4 is a liquid-cooled power module in the Altivar Process Modular range, designed for motor protection and drive power stages in the 380 to 480 VAC three-phase range. It's a cabinet-mount unit — not a standalone drive — sized for integration into a larger drive system cabinet, with a 337 mm depth, 229 mm width, and 322 mm height that dictate the enclosure layout. The liquid cooling loop handles the thermal load, which means the cabinet's air-handling only needs to manage the control and auxiliary electronics, not the main power stage. Supply voltage is 380...480 VAC three-phase, with a ±10 % tolerance on both ends. Switching frequency is configurable from 2 to 4.9 kHz. Operating temperature is -10 to 40 °C without derating, and up to 50 °C with a derating factor applied. Altitude derating kicks in above 1000 m, with a maximum operating altitude of 4800 m. The IP rating is IP00 on the bare module, but the cabinet integration path can achieve IP21 or IP66 depending on the enclosure design; the UL Type 1 and Type 12 ratings follow the same cabinet-dependent logic. ## Environmental and EMC posture The module carries a pollution degree 2 rating per IEC 61800-5-1, which is the standard for controlled environments — no conductive dust or moisture expected inside the cabinet. For harsher plant air, the chemical and dust resistance classes (3C3 and 3S3 per IEC 60721-3-3) give some margin, but the cabinet seal is what actually keeps the environment out. EMC immunity is specified at test levels 3 or 4 across the standard suite (ESD, radiated, fast transient, surge, conducted) — that's a solid industrial-grade immunity profile, not a residential or light-industrial one. The CE marking and the listed standards (UL 61800-5-1, IEC 61800-3, IEC 61508, IEC 13849-1) cover safety and functional safety bases, which matters if the drive system is part of a safety-related control function. ## Cabinet integration notes Mounting is vertical inside the cabinet. The 337 mm depth is the dimension to check against the cabinet depth.","metaTitle":"Schneider APM1L0MPMN4 Altivar Process Modular Power Module,","metaDescription":"Active production power module for Altivar Process Modular drives. 380-480 VAC, liquid-cooled, cabinet mount. UL 61800-5-1, IEC 61800-3. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"337 mm","Width":"229 mm","Height":"322 mm","Marking":"CE","Standards":"UL 61800-5-1 IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","Mounting mode":"Cabinet mount","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Operating position":"Vertical integrated in cabinet","Switching frequency":"2...4.9 kHz","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP21 (for cabinet integration) conforming to IEC 61800-5-1 IP66 (for cabinet integration) conforming to IEC 61800-5-1","Network number of phases":"3 phases","Product or component type":"Power module","[Us] rated supply voltage":"380...480 V - 10...10 %","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/APM1L0MPMN4/motor-protection-module-altivar-process-modular-380480v-liquid-cooled/","alternativesUrl":"https://aoctrl.com/api/mcp/products/APM1L0MPMN4/alternatives.json"},"ai":{"faq":[{"question":"What are the key physical dimensions for cabinet layout?","answer":"The module measures 337 mm deep, 229 mm wide, and 322 mm high. It mounts vertically inside a cabinet, and the depth is the critical dimension for enclosure fit — account for liquid cooling hose routing behind the module."},{"question":"What compliance standards does the APM1L0MPMN4 meet?","answer":"It carries CE marking and complies with UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The UL Type 1 and Type 12 ratings apply when integrated into a suitable cabinet."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM1L0MPMN4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM1L0MPMN4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}