{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM6B0CTLY6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM6B0CTLY6","canonicalUrl":"https://aoctrl.com/schneider/APM6B0CTLY6","factsUrl":"https://aoctrl.com/api/mcp/products/APM6B0CTLY6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular APM control module, APM6B0CTLY6, low-harmonic single drive, 500...690 V, STO SIL 3, IP00.","salesMarkdown":"The APM6B0CTLY6 is the control module for a low-harmonic ATV600 single drive, rated 500...690 V supply. It carries STO (safe torque off) rated SIL 3, and its internal supply rails are split: 24 V DC (19...30 V) for digital inputs, a separate 24 V DC (21...27 V) rail for digital inputs and STO, and a 10.5 V DC ±5 % reference supply for a 1 to 10 kOhm potentiometer. The module is IP00, so it lives inside a panel with forced convection — dissipation runs 2390 W at 2.5 kHz switching frequency. ## Communications & compliance On the communications side, the module carries Ethernet (Modbus TCP, 10/100 Mbit/s, half/full duplex with autonegotiation) and a 2-wire RS-485 Modbus serial port (4.8 to 38.4 kbit/s, RTU frame, 1...247 addresses). The remote graphic terminal adds RJ45 connectors for both Ethernet and serial. Compliance stack includes IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61508 and IEC 13849-1 (functional safety), plus IEC 61000-3-12 for harmonics — THDI <48 % at full load. Pollution degree 2, vibration resistance per IEC 60068-2-6, and chemical/dust resistance class 3C3/3S3 per IEC 60721-3-3.","metaTitle":"Schneider APM6B0CTLY6 Altivar Process Control Module, 500-69","metaDescription":"APM6B0CTLY6 low-harmonic ATV600 control unit. Active lifecycle. STO SIL 3, 500-690V supply, Ethernet/Modbus TCP. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"APM6B0CTLY6","Supply":"External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), 1 MOhm 500 V DC for 1 minute to earth","Marking":"CE","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","Data format":"8 bits, configurable odd, even or no parity for Modbus serial","Noise level":"69 dB conforming to 86/188/EEC","description":"low Harmonic ATV600 control unit, APM, single drive, 500...690V","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Connector type":"RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP RJ45 (on the remote graphic terminal) for Modbus serial","Safety function":"STO (safe torque off) SIL 3","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"7 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"APM","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Transmission rate":"10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Physical interface":"2-wire RS 485 for Modbus serial","Transmission frame":"RTU for Modbus serial","Number of addresses":"1...247 for Modbus serial","Discrete input logic":"16 preset speeds","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.012/50 Hz","Type of polarization":"No impedance for Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Power dissipation in W":"Forced convection: 2390 W, switching frequency 2.5 kHz","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP00 conforming to IEC 60529","Product or component type":"Control module","[Us] rated supply voltage":"500...690 V","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6bb004bfc0a0f490c3255068cd5016ba.pdf","sourceUrl":"https://www.se.com/nl/en/product/APM6B0CTLY6/low-harmonic-atv600-control-unit-apm-single-drive-500690v/"},"ai":{"faq":[{"question":"What supply voltages does the APM6B0CTLY6 require?","answer":"The main power supply is 500...690 V. Digital inputs and STO each have a dedicated 24 V DC rail (19...30 V for inputs, 21...27 V for STO/inputs). The reference potentiometer supply is 10.5 V DC ±5 %."},{"question":"What safety functions does the APM6B0CTLY6 support?","answer":"It includes STO (safe torque off) rated SIL 3 per IEC 61508 and IEC 13849-1."},{"question":"What communication protocols are available on this module?","answer":"Ethernet/Modbus TCP (10/100 Mbit/s) and Modbus serial over 2-wire RS-485 (4.8 to 38.4 kbit/s, RTU frame)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM6B0CTLY6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM6B0CTLY6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}