{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM6L0CTLN4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM6L0CTLN4","canonicalUrl":"https://aoctrl.com/schneider/APM6L0CTLN4","factsUrl":"https://aoctrl.com/api/mcp/products/APM6L0CTLN4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular, APM6L0CTLN4, control module for liquid-cooled ATV600 drives, 380...480 V, IP00.","salesMarkdown":"## Standards and environmental fit The APM6L0CTLN4: This module carries CE marking and is designed to a dense stack of IEC and UL standards: IEC 61800-3 (EMC for drive systems), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic limits), IEC 60721-3 (environmental classification), plus functional safety standards IEC 61508 and IEC 13849-1, and UL 61800-5-1. Pollution degree 2 per IEC 61800-5-1, which is the typical industrial environment — non-conductive pollution that can become conductive only with condensation. The environmental resistance is rated class 3C3 (chemical) and 3S3 (dust) per IEC 60721-3-3, so it's built for the dirty, chemically aggressive conditions you find in water/wastewater or heavy process plants. ## Ruggedness and installation constraints The operating ambient range is -10...50 °C, storage -40...70 °C. Vibration resistance is 1.5 mm peak-to-peak at 2-13 Hz and 0.5 gn at 13-200 Hz; shock resistance is 4 gn for 11 ms. Operating altitude goes up to 4800 m with current derating above 1000 m. Relative humidity tolerance is 5...95% without condensation. Insulation resistance is > 1 MOhm at 500 V DC for 1 minute to earth. These numbers tell you the module can handle the mechanical and thermal stress of a typical drive cabinet on a plant floor, but it needs the cabinet to keep out dust and water. ## EMC immunity Electromagnetic compatibility is specified with immunity test levels per IEC 61000-4-2 (ESD level 3), IEC 61000-4-3 (radiated RF level 3), IEC 61000-4-4 (fast transient level 4), IEC 61000-4-5 (surge 1.2/50 µs - 8/20 µs level 3), and IEC 61000-4-6 (conducted RF level 3). Level 4 on fast transients is notably aggressive — that's the kind of immunity you need when the drive is in a panel with contactors and relays switching inductive loads. Level 3 on the others is standard for industrial drives. No surprises here for an Altivar Process series module.","metaTitle":"Schneider APM6L0CTLN4 Altivar Process Control Module, 380-48","metaDescription":"Active Schneider Altivar Process Modular control module for liquid-cooled ATV600 drives. Rated 380-480V, IP00, CE+UL+functional safety. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"131 mm","Width":"230 mm","Height":"510 mm","Marking":"CE","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 618000-5-1","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1","Product or component type":"Control module","[Us] rated supply voltage":"380...480 V 24 V","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/APM6L0CTLN4/atv600-control-unit-modular-drive-380480v-for-liquid-cooled/","alternativesUrl":"https://aoctrl.com/api/mcp/products/APM6L0CTLN4/alternatives.json"},"ai":{"faq":[{"question":"What are the key standards this module complies with?","answer":"It carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1."},{"question":"What is the operating temperature range?","answer":"The ambient air temperature for operation is -10 to 50 °C. Storage range is -40 to 70 °C."},{"question":"What is the IP rating?","answer":"IP00 per IEC 61800-5-1. It requires installation inside an enclosure that provides the environmental seal."},{"question":"What is the supply voltage?","answer":"Rated supply voltage is 380...480 V with a 24 V auxiliary supply."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM6L0CTLN4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM6L0CTLN4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}