{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM6L0CTLY6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM6L0CTLY6","canonicalUrl":"https://aoctrl.com/schneider/APM6L0CTLY6","factsUrl":"https://aoctrl.com/api/mcp/products/APM6L0CTLY6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular, control module, APM6L0CTLY6, 500-690 V, IP00, CE, UL 618000-5-1, active.","salesMarkdown":"The Schneider APM6L0CTLY6 is the control module for the Altivar Process Modular drive family, specifically the variant for liquid-cooled systems. It handles the brains of the drive — logic, I/O, fieldbus communication — while the power stage is a separate module. Rated supply voltage is 500...690 V with a 24 V control supply, so it's built for medium-voltage industrial motors in process applications like pumps, fans, and conveyors. Physical footprint: 510 mm high, 230 mm wide, 131 mm deep. That's a tall, narrow module — expect it to occupy a full vertical slot in a multi-drive cabinet. IP00 means no enclosure; it's designed to be mounted inside a panel that provides the actual environmental seal. Environmental tolerance is solid for a drive control module: -10 to 50 °C operating, 5-95% humidity non-condensing, and altitude up to 4800 m with derating above 1000 m. Vibration resistance at 1.5 mm peak-to-peak (2-13 Hz) and 0.5 gn (13-200 Hz) per IEC 60068-2-6 means it can handle typical industrial floor vibration without nuisance trips. EMC immunity is specified at level 3 or 4 across electrostatic discharge, radiated RF, fast transients, surges, and conducted RF per IEC 61000-4-2 through -6. That's a robust spec for noisy plant environments — level 4 on fast transients is particularly relevant for drives near contactors or welding gear. ## Compliance and standards coverage This module carries CE marking and complies with IEC 61800-3 (EMC for drive systems), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic limits), IEC 60721-3 (environmental classification), IEC 61508 and IEC 13849-1 (functional safety), plus UL 618000-5-1. Pollution degree 2 per IEC 61800-5-1. That's a full suite for a drive destined for CE-marked machinery or UL-listed panels.","metaTitle":"Schneider APM6L0CTLY6 Altivar Process Control Module, 500-69","metaDescription":"Active Schneider Altivar Process Modular control module for liquid-cooled drives. Rated 500-690V, IP00, CE/UL/IEC 61800. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Depth":"131 mm","Width":"230 mm","Height":"510 mm","Marking":"CE","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 618000-5-1","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1","Product or component type":"Control module","[Us] rated supply voltage":"500...690 V 24 V","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/APM6L0CTLY6/atv600-control-unit-modular-drive-500690v-for-liquid-cooled/","alternativesUrl":"https://aoctrl.com/api/mcp/products/APM6L0CTLY6/alternatives.json"},"ai":{"faq":[{"question":"What is the supply voltage range for this control module?","answer":"The rated supply voltage is 500...690 V with a separate 24 V control supply. It is designed for liquid-cooled drive systems."},{"question":"What compliance standards does the APM6L0CTLY6 meet?","answer":"It carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 618000-5-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM6L0CTLY6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM6L0CTLY6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}