{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM9L0CTLN4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM9L0CTLN4","canonicalUrl":"https://aoctrl.com/schneider/APM9L0CTLN4","factsUrl":"https://aoctrl.com/api/mcp/products/APM9L0CTLN4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular, APM9L0CTLN4 control module, 380...480 V, IP00, for liquid-cooled drives.","salesMarkdown":"The Schneider APM9L0CTLN4 is a control module within the Altivar Process Modular range, designed for liquid-cooled ATV900 drives. It operates on a 380...480 V supply and is rated IP00 per IEC 61800-5-1. This is the brain of the modular drive system — it handles the logic, communication, and control loop for the power stage. Standard lead times apply. We can quote against an RFQ and confirm availability against your schedule. Above 1000 m altitude, current derating applies up to 4800 m. Vibration resistance is 1.5 mm peak-to-peak at 2-13 Hz and 0.5 gn at 13-200 Hz; shock rated at 4 gn for 11 ms. EMC immunity is specified at level 3 for electrostatic discharge, radiated RF, conducted RF, and surge (1.2/50 µs - 8/20 µs), and level 4 for fast transients. This places it in a robust category for industrial electrical noise environments — suitable for installations near contactors, relays, and motor feeders without additional filtering in most cases. Carries CE marking and complies with IEC 61800-3 (EMC for drive systems), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic limits), IEC 60721-3 (environmental classification), IEC 61508 and IEC 13849-1 (functional safety), and UL 61800-5-1. Pollution degree 2 per IEC 61800-5-1. Insulation resistance > 1 MOhm at 500 V DC to earth.","metaTitle":"Schneider APM9L0CTLN4 Altivar Process Control Module, 380-48","metaDescription":"Active Schneider APM9L0CTLN4 Altivar Process Modular control module. Rated 380-480V, IP00, CE/UL compliant. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"131 mm","Width":"230 mm","Height":"510 mm","Marking":"CE","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 618000-5-1","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1","Product or component type":"Control module","[Us] rated supply voltage":"380...480 V 24 V","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/APM9L0CTLN4/atv900-control-unit-modular-drive-380480v-for-liquid-cooled/","alternativesUrl":"https://aoctrl.com/api/mcp/products/APM9L0CTLN4/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of the APM9L0CTLN4?","answer":"Height 510 mm, width 230 mm, depth 131 mm."},{"question":"What supply voltage does the APM9L0CTLN4 require?","answer":"Rated supply voltage is 380...480 V AC, with a 24 V control supply."},{"question":"What compliance standards does the APM9L0CTLN4 meet?","answer":"CE marked, compliant with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM9L0CTLN4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM9L0CTLN4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}