{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APM9L0CTLY6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APM9L0CTLY6","canonicalUrl":"https://aoctrl.com/schneider/APM9L0CTLY6","factsUrl":"https://aoctrl.com/api/mcp/products/APM9L0CTLY6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular APM9L0CTLY6 control module, 500...690 V, IP00, for liquid-cooled ATV900 drives.","salesMarkdown":"The APM9L0CTLY6 is the control module for the Altivar Process Modular drive series, designed for liquid-cooled ATV900 cabinets. It operates on a 500...690 V supply with a separate 24 V control voltage, meaning it handles medium-voltage motor loads common in industrial process lines — pumps, fans, compressors — where liquid cooling keeps the drive cabinet compact. The module carries CE marking and complies with IEC 61800-3 (EMC for power drive systems), IEC 61800-5-1 (safety), IEC 61508 (functional safety), and IEC 13849-1 (machine safety). UL 618000-5-1 listing means it is accepted for North American installations — a single control module that clears both IEC and UL regulatory gates. Rated IP00 — no enclosure, so it mounts inside a drive cabinet that provides the IP protection. Operating range is -10 to 50 °C ambient; above 40 °C you will want to check the drive's thermal derating curve. Storage can go from -40 to 70 °C, which covers most shipping and site idle conditions. Vibration resistance is 1.5 mm peak-to-peak at 2-13 Hz and 0.5 gn at 13-200 Hz per IEC 60068-2-6. Shock rated at 4 gn for 11 ms per IEC 60068-2-27. These numbers mean the module survives normal shipping vibration and occasional floor impact — not continuous high-g machinery shock. Pollution degree 2 per IEC 61800-5-1, so non-conductive dust only; keep the cabinet clean. Altitude rating goes to 4800 m with current derating above 1000 m — typical for drives installed in high-altitude plants or mine sites. Environmental class 3C3 (chemical resistance) and 3S3 (dust) per IEC 60721-3-3, meaning it withstands industrial atmospheres with moderate pollutants. ## EMC immunity — what the levels mean The module meets ESD immunity level 3 (6 kV contact / 8 kV air per IEC 61000-4-2), radiated RF level 3 (10 V/m), fast transient level 4 (4 kV), surge level 3 (2 kV line-to-earth / 1 kV line-to-line), and conducted RF level 3 (10 V). Level 4 on fast transients is the highest standard test — this control module is built for electrically noisy environments like VFD cabinets and welding lines. Insulation resistance >1 MΩ at 500 V DC to earth for 1 minute.","metaTitle":"Schneider APM9L0CTLY6 Altivar Process Control Module, 500-69","metaDescription":"APM9L0CTLY6 control module for ATV900 liquid-cooled drives. Rated 500-690 V, IP00, active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Depth":"131 mm","Width":"230 mm","Height":"510 mm","Marking":"CE","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 618000-5-1","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm 500 V DC for 1 minute to earth","IP degree of protection":"IP00 conforming to IEC 61800-5-1","Product or component type":"Control module","[Us] rated supply voltage":"500...690 V 24 V","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/APM9L0CTLY6/atv900-control-unit-modular-drive-500690v-for-liquid-cooled/","alternativesUrl":"https://aoctrl.com/api/mcp/products/APM9L0CTLY6/alternatives.json"},"ai":{"faq":[{"question":"What are the key standards this module complies with?","answer":"It complies with IEC 61800-3 (EMC for drive systems), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic limits), IEC 60721-3 (environmental), IEC 61508 and IEC 13849-1 (functional safety), and UL 618000-5-1. CE marked."},{"question":"What is the operating temperature range?","answer":"Operating ambient is -10 to 50 °C. Storage range is -40 to 70 °C."},{"question":"What is the IP rating?","answer":"IP00 per IEC 61800-5-1 — no built-in enclosure protection. It must be installed inside a drive cabinet that provides the required IP rating for the environment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APM9L0CTLY6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APM9L0CTLY6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}