{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APMCA02LCY6RH","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APMCA02LCY6RH","canonicalUrl":"https://aoctrl.com/schneider/APMCA02LCY6RH","factsUrl":"https://aoctrl.com/api/mcp/products/APMCA02LCY6RH","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular APMCA02LCY6RH, power filter, 500...690 V, 200 A, IP00, 3-phase, cabinet mount.","salesMarkdown":"The Schneider APMCA02LCY6RH is a power filter from the Altivar Process Modular line, rated for 500...690 V three-phase supplies and carrying a line current of 200 A at 690 V for normal duty, 163 A for heavy duty. The 200 A normal-duty / 163 A heavy-duty split at 690 V tells you this filter is sized for the input side of a drive cabinet where the motor load is known. Normal duty covers the continuous current draw; heavy-duty is the headroom for overload cycles. The integrated EMC filter is rated for 300 m cable runs at category C3 — that's the conducted emission limit for industrial second-environment networks, not residential. If your installation runs longer cable or needs C2, you'll need an external output filter downstream. Cabinet-mount only, IP00. Dimensions: 1249 mm high, 269 mm wide, 506 mm deep. Vertical operating position is mandatory. CE marked, with UL 61800-5-1 and IEC 61800-5-1 safety standards. Pollution degree 2, so it's rated for normal industrial atmospheres with only non-conductive dust. Environmental class 3C3 (chemical resistance) and 3S3 (dust) per IEC 60721-3-3 — that's the standard for fixed, weather-protected locations. Operating temperature is -10 to 40 °C without derating, up to 50 °C with derating.","metaTitle":"Schneider APMCA02LCY6RH Altivar Process Modular Power Filter","metaDescription":"Active production Schneider APMCA02LCY6RH power filter, 200 A at 690 V, IP00, cabinet mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Depth":"506 mm","Width":"269 mm","title":"APMCA02LCY6RH","Height":"1249 mm","Marking":"CE","Standards":"UL 61800-5-1 IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 300 m category C3","description":"electronic filtering power supply, 690V, 200A, IP00, 3 phases","Line current":"200 A at 500 V (normal duty) 200 A at 690 V (normal duty) 163 A at 500 V (heavy duty) 163 A at 690 V (heavy duty)","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Mounting mode":"Cabinet mount","Apparent power":"239 kVA normal duty 195 kVA heavy duty","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Device short name":"APM","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 2000 m with current derating above 1000m","Operating position":"Vertical integrated in cabinet","Prospective line Isc":"50 kA","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm at 500 V, between supply and earth terminals","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP00 conforming to IEC 60529","Network number of phases":"3 phases","Product or component type":"Power filter","[Us] rated supply voltage":"500...690 V - 10...10 %","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d99b6e37f52215379e25f9b3c0c0b053.pdf","sourceUrl":"https://www.se.com/nl/en/product/APMCA02LCY6RH/electronic-filtering-power-supply-690v-200a-ip00-3-phases/"},"ai":{"faq":[{"question":"What are the key ratings for this power filter?","answer":"Rated supply voltage 500...690 V, line current 200 A at 690 V normal duty / 163 A heavy duty, apparent power 239 kVA normal duty / 195 kVA heavy duty, IP00 enclosure, cabinet mount."},{"question":"What compliance documentation is available?","answer":"CE marking, UL 61800-5-1, IEC 61800-5-1, IEC 61800-3, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1. Environmental class 3C3/3S3 per IEC 60721-3-3."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APMCA02LCY6RH","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APMCA02LCY6RH when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}