{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"APMCA03LCN4RH","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"APMCA03LCN4RH","canonicalUrl":"https://aoctrl.com/schneider/APMCA03LCN4RH","factsUrl":"https://aoctrl.com/api/mcp/products/APMCA03LCN4RH","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process Modular APM series, APMCA03LCN4RH power filter, 380-480 V, 268 A normal duty, IP00, cabinet mount.","salesMarkdown":"The APMCA03LCN4RH is a power filter in the Altivar Process Modular (APM) family, designed to sit between the mains and an APM drive module. It cleans up line-side harmonics and provides the integrated EMC filter — rated for 300 m cable runs at category C3 — so the drive meets IEC 61800-3 conducted emission limits without an external box. The filter is rated for 380-480 V three-phase, and the line current tells you which drive it pairs with: 278 A at 380 V normal duty, 268 A at 480 V normal duty, and 233 A / 218 A heavy duty at those voltages. That 268 A at 480 V is the number to match against your drive's input rating. Total harmonic distortion of line current stays under 48 % at full load per IEC 61000-3-12, which keeps the plant's distribution transformer from overheating on a multi-drive line. Apparent power works out to 223 kVA normal duty, 181 kVA heavy duty — useful for sizing the upstream breaker and cable. Cabinet-mount only, vertical position, IP00 — meaning no enclosure of its own, so it goes inside a panel that provides the actual ingress protection. Dimensions are 1249 mm high, 269 mm wide, 506 mm deep. That height is the main constraint: you need a cabinet tall enough to clear the filter assembly and leave room for cable bending at the top and bottom. Operating temperature range is -10 to 40 °C without derating, and up to 50 °C with a derating factor. Pollution degree 2 per IEC 61800-5-1 (non-conductive, occasional condensation). Environmental class 3C3 for chemical resistance and 3S3 for dust — standard for industrial process areas with moderate contamination. Insulation resistance is > 1 MOhm at 500 V between supply and earth. Shock resistance is 4 gn for 11 ms, vibration resistance is 1.5 mm peak-to-peak at 2-13 Hz and 0.5 gn at 13-200 Hz — both per IEC 60068-2-6. These numbers matter if the cabinet is on a machine that sees frequent starts or floor vibration.","metaTitle":"Schneider Electric APMCA03LCN4RH Altivar Process Modular Pow","metaDescription":"Active production power filter for Altivar Process Modular drives. 380-480 V, 268 A normal duty, IP00, cabinet mount. Integrated EMC filter C3. UL/IEC compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"506 mm","Width":"269 mm","title":"APMCA03LCN4RH","Height":"1249 mm","Marking":"CE","Standards":"UL 61800-5-1 IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 300 m category C3","description":"electronic filtering power supply, 400V, 268A, IP00, 3 phases","Line current":"278 A at 380 V (normal duty) 268 A at 480 V (normal duty) 233 A at 380 V (heavy duty) 218 A at 480 V (heavy duty)","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Mounting mode":"Cabinet mount","Apparent power":"223 kVA normal duty 181 kVA heavy duty","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process Modular","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27","Device short name":"APM","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"<= 4800 m with current derating above 1000m","Operating position":"Vertical integrated in cabinet","Prospective line Isc":"50 kA","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Insulation resistance":"> 1 MOhm at 500 V, between supply and earth terminals","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP00 conforming to IEC 60529","Network number of phases":"3 phases","Product or component type":"Power filter","[Us] rated supply voltage":"380...480 V - 10...10 %","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/febc65e1035eb56ed38739639bcf0dd5.pdf","sourceUrl":"https://www.se.com/ca/en/product/APMCA03LCN4RH/electronic-filtering-power-supply-400v-268a-ip00-3-phases/"},"ai":{"faq":[{"question":"What are the key ratings I need to match for fit?","answer":"The filter is rated for 380-480 V three-phase, 268 A at 480 V normal duty (278 A at 380 V normal duty), and 218 A at 480 V heavy duty (233 A at 380 V heavy duty). Apparent power is 223 kVA normal duty, 181 kVA heavy duty. It includes an integrated EMC filter for 300 m cable runs, category C3."},{"question":"What compliance documentation does this filter carry?","answer":"CE marked. Complies with UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Prospective short-circuit rating is 50 kA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/APMCA03LCN4RH","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/APMCA03LCN4RH when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}