{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATH650D45N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATH650D45N4","canonicalUrl":"https://aoctrl.com/schneider/ATH650D45N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATH650D45N4","rawCanonicalId":null},"summary":{"shortDescription":"variable speed drive, Altivar HVAC ATH600, ATH650, 45kW, 60hp, 380 to 480V, 3 phase, IP55","salesMarkdown":null,"metaTitle":"ATH650D45N4 - Schneider Electric","metaDescription":"variable speed drive, Altivar HVAC ATH600, ATH650, 45kW, 60hp, 380 to 480V, 3 phase, IP55","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"340 mm","Width":"307 mm","Height":"948.5 mm","Supply":"External supply for control circuit: 24 V DC (19...30 V), Internal supply for digital inputs and STO: 24 V DC (20.4...27 V), Internal supply for reference potentiometer: 10.5 V DC +/- 5 %, <10 mA, protection type: short-circuit","Marking":"CE UKCA CULus EAC RCM ATEX WEEE ROHS KCC","Variant":"Standard version","Accuracy":"+/- 1.5 % (AI1, AI2, AI3) for a temperature variation 60 °C +/- 1 % (AQ1, AQ2) for a temperature variation 60 °C","Standards":"UL 61800-5-1 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 RoHS","EMC filter":"Class C2 EMC filter integrated","Data format":"8 bits, configurable odd, even or no parity 8 bits, no parity, 1 stop","Noise level":"69.7 dB","Option card":"Communication module for BACnet IP Communication module for PROFINET Communication module for Ethernet IP/Modbus TCP Digital and analog I/O extension module Output relay extension module","Line current":"79.8 A at 380 V (normal duty) 69 A at 480 V (normal duty) 67.1 A at 380 V (heavy duty) 59 A at 480 V (heavy duty)","Safety level":"SIL 3 conforming to IEC 61508 PL = e conforming to ISO 13849-1","Mounting mode":"Wall mount","Apparent power":"57.4 kVA (normal duty) 49.1 kVA (heavy duty)","Connector type":"RJ45 and open style terminals","Motor power hp":"60 hp for normal duty 50 hp for heavy duty","Motor power kW":"45 kW for normal duty 37 kW for heavy duty","Output voltage":"<= power supply voltage","Product weight":"50 kg","Linearity error":"AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output","Protection type":"Thermal overload protection: motor Safe torque off: motor Motor phase loss: motor Against exceeding limit speed: motor Temperature protection: drive Overheating: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Break on the control circuit: drive","Safety function":"STO (safe torque off)","lifecycle_stage":"current","Method of access":"Server Modbus RTU Subordinate BACnet MS/TP","Output frequency":"0.5 kHz","Pollution degree":"2","Range of product":"Altivar HVAC ATH600","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATH650","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Relay output type":"Relay outputs R1A, R1B, R1C: 1 NO 1 NC electrical durability 100000 cycles Relay outputs R2A, R2C: 1 NO electrical durability 100000 cycles Relay outputs R3A, R3C: 1 NO electrical durability 100000 cycles","Sampling duration":"2 ms + 0...0.5 ms DI1...DI6 digital input 5 ms + 0...1 ms DI5, DI6 pulse input 5 ms + 0...1 ms AI1, AI2, AI3 10 ms + 0...1 ms AQ1, AQ2 5 ms +/- 0.5 ms R1, R2, R3","Transmission rate":"4800 bps, 9600 bps, 19200 bps, 38.4 Kbps 9.6, 19.2, 38.4, 76.8 kbit/s","Function available":"Fire mode Forced fire mode Run permissive PID controller 3 additional PID Damper control Underload detection for broken belt Scroll compressor management Skipped frequencies Catch on the fly Power monitoring Cybersecure firmware update","Operating altitude":"1000 m without derating 1000...3000 m with current derating 1 % per 100 m","Operating position":"Vertical position","Physical interface":"2-wire RS 485","Transmission frame":"RTU MS/TP","Analogue input type":"AI1: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits AI2: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 12 bits AI3: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 12 bits AI2, AI3 PTC/PT 100/PT 1000/KTY84 temperature probe","Discrete input type":"STOA, STOB safety input, 24 V DC DI1...DI6 digital input, 24 V DC, impedance: 4.4 kOhm DI5, DI6 programmable as pulse input: 0...30 kHz, 24 V DC","Input compatibility":"DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2","Number of addresses":"1...247 1...127","Product destination":"Asynchronous motors Synchronous motors","Relay output number":"3","Switching frequency":"2...16 kHz adjustable with derating factor","Analogue output type":"Software-configurable voltage AQ1, AQ2: 0...10 V impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits","Discrete input logic":"Positive logic (source) (DI1...DI6), Positive logic (source) (STOA, STOB), Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1)","Prospective line Isc":"50 kA","Type of polarization":"120 ohm termination or no impedance","Analogue input number":"3","Braking to standstill":"By DC injection","Discrete input number":"8","Analogue output number":"2","Cybersecurity function":"True","Nominal Output Current":"88 A at 380 V (normal duty) 88 A at 480 V (normal duty) 74.5 A at 380 V (heavy duty) 74.5 A at 480 V (heavy duty)","Power dissipation in W":"1210 W, switching frequency 4 kHz (normal duty) 903 W, switching frequency 4 kHz (heavy duty)","IP degree of protection":"IP55","Motor slip compensation":"Adjustable Automatic whatever the load Can be suppressed Not available with synchronous motors","Brake chopper integrated":"False","Network number of phases":"3 phases","Maximum switching current":"Relay output R1, R2, R3 on resistive load load: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load load: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load load, cos phi = 0.4 and L/R = 0.7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load load, cos phi = 0.4 and L/R = 0.7 ms: 2 A at 30 V DC","Maximum transient current":"96.8 A during 60 s (normal duty) 111.8 A during 60 s (heavy duty)","Minimum switching current":"Relay output R1, R2, R3: 5 mA at 24 V DC","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Communication port protocol":"Modbus serial BACnet MS/TP","Nominal switching frequency":"4 kHz","Product specific application":"HVAC","4 Quadrant Operation Possible":"False","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Cybersecurity level and standard":"Security level (SL) 1 conforming to IEC 62443-4-2","Synchronous motor control profile":"Vector control without sensor","Asynchronous motor control profile":"Voltage/frequency ratio, 5 points Flux vector control with sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points","Acceleration and deceleration ramps":"Acceleration/deceleration ramp adaptation Linear S, U or customized","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-15...40 °C without derating 40...50 °C with derating factor","Power Loss Static Current Independent":"31 W","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3 Class 3B1 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","With safety function Safe torque off (STO)":"True","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"15 gn at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"1 gn at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATH650D45N4/variable-speed-drive-altivar-hvac-ath600-ath650-45kw-60hp-380-to-480v-3-phase-ip55/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATH650D45N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATH650D45N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}