{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A10003333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A10003333","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A10003333","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A10003333","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A10003333, medium-voltage AC drive, 836 kW motor power, 1000 kVA, 2970-3630 V supply, 18-pulse rectifier, floor-standing enclosure.","salesMarkdown":"## Physical footprint and site integration The ATV1200A10003333: This Altivar 1200 drive ships in a floor-standing enclosure with separate air flows for the power cells and transformer — not a cabinet you retrofit into an existing panel. Standard-efficiency configuration measures 3560 mm wide by 1400 mm deep by 2670 mm high; the high-efficiency variant adds width to 3860 mm and depth to 1500 mm while keeping the same 2670 mm height. The cooling system moves 13,200 m³/h in standard efficiency and 19,800 m³/h in high efficiency — that volume has to be ducted or room-conditioned, not just vented. Noise output is 80 dB, which places this drive in a separate electrical room or a dedicated enclosure area, not on a production floor near operators. ## Power stage and input topology Rated for 836 kW motor power at 1000 kVA apparent power, with a supply voltage window of 2970 to 3630 V. The input stage is an 18-pulse diode rectifier bridge — that topology cancels the 5th and 7th harmonics at the transformer secondary, so the drive meets IEEE 519 without a separate active filter on most utility feeds. Output voltage tracks the supply voltage (no buck/boost), so the motor sees whatever the incoming line delivers under load. Prospective short-circuit withstand is 31.5 kA for 150 ms — the upstream protection must coordinate to clear within that window or the drive's internal bracing becomes the weak link. ## Overload capability and duty cycle Two overload profiles are available. Standard overload handles 1.2× rated current for 60 seconds and 1.5× for 3 seconds. High overload pushes to 1.5× for 60 seconds and 1.85× for 3 seconds. The high-overload setting is the one to specify if the driven load has intermittent peak torque demands — a crusher, a centrifuge, or a loaded conveyor start. ## Control complement and isolation Six discrete inputs standard (expandable to ten) and four analogue inputs, all software-configurable for 0–20 mA or 4–20 mA. Two analogue outputs follow the same current-loop range. Electrical isolation between power and control is maintained, so the 24 V DC control circuits stay referenced to ground even when the 3 kV power stage faults. The control supply requires an external 220 V AC source at 3 kVA — it does not derive from the DC bus. The cooling fan has its own internal 380 V AC supply, with an optional external 380 V AC feed for redundancy. This separation means the control electronics stay alive during a DC-bus discharge cycle. CE marked, designed to EN/IEC 61800-3 (EMC environment), EN/IEC 61800-4 (harmonics), EN/IEC 61800-5-1 (electrical safety), EN/IEC 60204-11 (machinery), and EN/IEC 60529 (enclosure protection). Pollution degree 2 per EN/IEC 61800-5-1 — suitable for controlled electrical rooms where conductive dust is not present. Overvoltage category II, meaning the drive is intended for connection downstream of a transformer, not at the service entrance. Dielectric strength tested at 10 kV AC between earth and power terminals — this is the withstand voltage for the insulation system, not a continuous rating. The drive includes integrated ground fault protection and an integrated EMC filter. ## Sourcing and lifecycle position Lifecycle status is current production. The drive is assembled from two plinths, a phase-shifting transformer, nine power cells, medium-voltage arrestors, cooling fans, and a human-machine interface.","metaTitle":"Schneider ATV1200A10003333 AC Drive, 836 kW, 2970-3630 V","metaDescription":"Schneider Electric ATV1200A10003333 Altivar 1200 AC drive, 836 kW motor power, 1000 kVA, 18-pulse input. Current production; quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"3560 mm (standard efficiency) 3860 mm (high efficiency)","Height":"2670 mm high efficiency 2670 mm standard efficiency","Current":"200 A","IP Rating":"IP41 / IP31 / IP42","Input Type":"18 pulse diode rectifier bridge","Coil Voltage":"220 V","Product Status":"Active","Protection Type":"Ground fault protection: drive","Pollution Degree":"Pollution degree 2","Temp Storage Max":"60 °C","Temp Storage Min":"-10 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"50 °C","Temp Operating Min":"0 °C","Temperature Storage":"-10...60 °C","Ambient Air Temperature Operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A10003333/medium-voltage-variable-speed-drive-atv1200-3-3-kv-1000-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV1200A10003333/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A10003333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A10003333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}