{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A10406060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A10406060","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A10406060","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A10406060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A10406060 medium voltage AC drive, 869 kW motor power, 1040 kVA apparent power, 2970-3630 V supply, 30-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Medium voltage drive for 869 kW motor loads The ATV1200A10406060 is a Schneider Electric Altivar 1200 medium voltage AC drive rated for 869 kW motor power with 1040 kVA apparent power. It accepts a 2970-3630 V supply through a 30-pulse diode rectifier input stage, which keeps line-side harmonics low enough to meet IEEE 519 without external filtering in most installations. This drive is built for asynchronous and synchronous motors in applications where a single drive handles a large pump, fan, compressor, or conveyor — the 869 kW rating puts it squarely in medium-voltage territory, typically 3.3 kV class. ## Overload profile and fault clearing The overload withstand profile gives you two operating modes: standard overload handles 1.2× rated current for 60 seconds and 1.5× for 3 seconds; high overload pushes to 1.5× for 60 seconds and 1.85× for 3 seconds. This matters when sizing for a high-inertia load that needs extended acceleration time — the high-overload curve keeps the drive online through the start transient without tripping. Dielectric strength is 20 kV AC between earth and power terminals, with prospective line short-circuit capacity rated at 31.5 kA for 150 ms. That SCCR figure tells you the upstream protection must clear a fault within that window or the drive's internal fault withstand is exceeded. ## Physical footprint and enclosure This drive ships as a floor-standing enclosure with separate air flows for the power cell section and the control compartment. Standard efficiency dimensions are 3160 mm wide × 1400 mm deep × 2590 mm high; the high-efficiency variant runs 3460 mm wide × 1600 mm deep × 2740 mm high. The cooling fan moves 19900 m³/h (standard) or 23200 m³/h (high efficiency) — plan for that airflow path and acoustic noise at 80 dB. Product composition includes the phase-shifting transformer, 15 power cells, medium-voltage arrestors, cooling fans, and the HMI. The transformer is integrated, not external — the whole assembly arrives as one unit, which simplifies site wiring but sets the minimum floor area and lifting requirements. ## I/O complement and control supply The drive provides 4 software-configurable analogue inputs (0-20 mA / 4-20 mA, 250 Ohm impedance), 2 analogue outputs (same current range), and 6 discrete inputs expandable to 10. The control supply requires 220 V AC at 3 kVA externally; the cooling fan runs on a separate 380 V AC supply. Electrical connection uses M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, entry from top or bottom. ## Standards and operating envelope CE marked and compliant with EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (thermal), EN/IEC 61800-5-1 (safety), EN/IEC 60204-11 (electrical equipment), and EN/IEC 60529 (enclosure protection). Operating altitude up to 1000 m with 0.6% current derating per additional 100 m up to 2000 m; relative humidity 0-90% standard, 0-95% optional. Vibration resistance tested at 4.9 m/s² over 10-50 Hz. The integrated EMC filter covers conducted emissions for the CE declaration — no external filter box needed for standard industrial environments.","metaTitle":"Schneider Electric ATV1200A10406060 AC Drive, 869 kW","metaDescription":"Schneider Electric ATV1200A10406060 Altivar 1200 medium voltage drive. 869 kW motor power, 1040 kVA, 30-pulse rectifier. CE marked, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"1400 mm (standard efficiency) 1600 mm (high efficiency)","Width":"3460 mm (high efficiency) 3160 mm (standard efficiency)","Height":"2590 mm standard efficiency 2740 mm high efficiency","Current":"100 A","IP Rating":"IP31 / IP42 / IP41","Input Type":"30 pulse diode rectifier bridge","Coil Voltage":"220 V","Product Status":"Active","Protection Type":"Ground fault protection: drive","Pollution Degree":"Pollution degree 2","Temp Storage Max":"60 °C","Temp Storage Min":"-10 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"50 °C","Temp Operating Min":"0 °C","Temperature Storage":"-10...60 °C","Ambient Air Temperature Operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A10406060/medium-voltage-variable-speed-drive-atv1200-6-kv-1040-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV1200A10406060/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A10406060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A10406060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}