{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A115001010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A115001010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A115001010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A115001010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A115001010 medium-voltage variable frequency drive, 9614 kW motor power, 2970-3630 V supply, 48-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Medium-voltage drive, 9614 kW, 48-pulse input The ATV1200A115001010 is a Schneider Electric Altivar 1200 medium-voltage variable frequency drive rated for 9614 kW motor power at a supply voltage of 2970-3630 V AC. It uses a 48-pulse diode rectifier bridge on the input stage, which means the line-side harmonics are low enough that you can often skip a separate harmonic filter — the 48-pulse topology cancels the 5th, 7th, 11th, and 13th harmonics at the transformer secondary. This is a floor-standing enclosure with separate air flows for the power cells and the phase-shifting transformer. The drive composition includes 24 power cells, a phase-shifting transformer, medium-voltage arrestors, cooling fans, and a human-machine interface. It is designed for asynchronous motor control in applications where a single drive handles a large load — pumps, fans, compressors, conveyors in mining, cement, oil and gas, or water treatment. ## Electrical ratings and overload profile The drive delivers output voltage up to the supply voltage level and draws 720 A line current. Apparent power rating is 11500 kVA. The overload capability is defined in two duty classes: standard overload allows 1.2× In for 60 seconds and 1.5× In for 3 seconds; high overload allows 1.5× In for 60 seconds and 1.85× In for 3 seconds. This matters for sizing the drive to the load — if your process has short-duration peak torque demands (crushers, mills), the high-overload profile gives you the headroom without oversizing to the next frame. The prospective line short-circuit current withstand is 31.5 kA for 150 ms, and dielectric strength between earth and power terminals is 28 kV AC. These numbers tell you the drive can ride through a bolted fault on the incoming line without catastrophic failure, and the insulation system meets the clearance requirements for a 3.3 kV class medium-voltage drive. Pollution degree 2 per EN/IEC 61800-5-1 applies — the enclosure keeps conductive dust and moisture out of the live parts. ## Physical footprint and installation constraints Altitude derating applies above 1000 m: 0.6 % current derating per 100 m up to 2000 m. If your site is at 1500 m, budget a 3 % reduction in available output current. The supply voltage range is 2970-3630 V, so the drive can ride through typical utility voltage sags on a 3.3 kV system without dropping out. Electrical connection uses M10 bar-type screw terminals accepting up to 6 × 40 mm² conductors per phase, entry from the bottom or top. The drive carries CE marking and is designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The integrated EMC filter covers conducted emissions for the second environment (industrial) per EN/IEC 61800-3. No official successor or cross-reference exists — this is the current Altivar 1200 offering for the 3.3 kV, 9614 kW rating point.","metaTitle":"Schneider ATV1200A115001010 Altivar 1200 VFD, 9614 kW","metaDescription":"Schneider Electric ATV1200A115001010 medium-voltage VFD, 9614 kW motor power, 2970-3630 V supply. 48-pulse diode rectifier, integrated EMC filter.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1600 mm (standard efficiency)","Width":"15080 mm (standard efficiency)","title":"ATV1200A115001010","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"48 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 10 kV - 11500 kVA","Line current":"720 A","Apparent power":"11500 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"9614 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"28 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 24 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"140000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP31 IP41","Network number of phases":"3 phases","Continuous output current":"664 A (standard overload) 531 A (high overload)","Maximum transient current":"797 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"10 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Closed-loop control with encoder Sensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"375 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A115001010/medium-voltage-variable-speed-drive-atv1200-10-kv-11500-kva/"},"ai":{"faq":[{"question":"Where can I buy the ATV1200A115001010 and get a price?","answer":"The ATV1200A115001010 is sourced to order against the BOM. Submit an RFQ for current pricing and lead time confirmation. This is a project-scale medium-voltage drive — availability is confirmed at quote time, not held as shelf stock."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A115001010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A115001010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}