{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A14003333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A14003333","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A14003333","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A14003333","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A14003333, medium-voltage AC drive, 1170 kW motor power, 3.3 kV supply, 280 A line current, 18-pulse rectifier, floor-standing enclosure.","salesMarkdown":"## What this drive is built for This is the Altivar 1200, Schneider's medium-voltage drive family for large induction and synchronous motors. The ATV1200A14003333 variant is rated for 1170 kW motor power at a supply voltage of 2970...3630 V, drawing 280 A line current and delivering 1400 kVA apparent power. The 18-pulse diode rectifier input stage reduces line current harmonics without an external filter — a real advantage when the utility or plant power quality standards demand low THID at the point of common coupling. ## Physical footprint and installation reality This is not a panel-mount drive. It ships as a floor-standing enclosure with separate air flows for the transformer and power cells. Standard efficiency footprint is 3560 mm wide, 1400 mm deep, 2820 mm high; high-efficiency versions add 300 mm to width and 200 mm to depth. Cooling is forced convection requiring 29900 m3/h (standard efficiency) or 33200 m3/h (high efficiency) of air volume. The noise level at full load is 80 dB — plan for ear protection if the drive sits near a walkway or operator station. Main power connection uses bar terminals with M10 screws, accepting up to 6 x 40 mm² cable per phase, entry from bottom or top. Control supply is 220 V AC at 3 kVA; internal fan supply is 380 V AC. ## Overload capability and protection The drive offers two overload profiles: standard overload handles 1.2× In for 60 seconds and 1.5× In for 3 seconds; high overload handles 1.5× In for 60 seconds and 1.85× In for 3 seconds. Pick the profile that matches your motor's duty cycle — high overload gives more headroom for starting heavy loads like crushers or centrifuge. Built-in ground fault protection covers the drive itself. Dielectric strength between earth and power terminals is 10 kV AC. The drive can withstand a prospective line short-circuit current of 31.5 kA for 150 ms. Operating altitude range is 1000...2000 m with current derating of 0.6 % per 100 m above 1000 m. Pollution degree 2 per EN/IEC 61800-5-1 applies — typical for a controlled electrical room environment. CE marked. Standards compliance includes EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3 (EMC), EN/IEC 61800-4, and EN/IEC 61800-5-1. Overvoltage category II per EN/IEC 61800-5-1. The integrated EMC filter simplifies installation in European markets. The drive composition includes a phase-shifting transformer, 9 power cells, medium-voltage arrestors, cooling fans, and a human-machine interface. Control isolation is electrical between power and control circuits. Sourced to order against your BOM quantity through independent distribution.","metaTitle":"Schneider Electric ATV1200A14003333 Altivar 1200, 1170 kW","metaDescription":"Schneider Electric ATV1200A14003333 medium-voltage VFD, 1170 kW motor power, 3.3 kV input, 18-pulse rectifier, CE marked. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1600 mm (high efficiency)","Width":"3560 mm (standard efficiency) 3860 mm (high efficiency)","title":"ATV1200A14003333","Height":"2820 mm standard efficiency 2820 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"18 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 3.3 kV - 1400 kVA","Line current":"280 A","Apparent power":"1400 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"1170 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"10 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer 9 x power cells Medium voltage arrestors Cooling fans Human machine interface","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"29900 m3/h (standard efficiency) 33200 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP41 IP31","Network number of phases":"3 phases","Continuous output current":"245 A (standard overload) 196 A (high overload)","Maximum transient current":"294 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"3.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder Vector control with sensor, optional Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"47 kW (standard efficiency) 41 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A14003333/medium-voltage-variable-speed-drive-atv1200-3-3-kv-1400-kva/"},"ai":{"faq":[{"question":"What motor power can ATV1200A14003333 drive?","answer":"It is rated for 1170 kW motor power, delivering 1400 kVA apparent power at 280 A line current. Suitable for both asynchronous (induction) and synchronous motors."},{"question":"What physical space does ATV1200A14003333 require?","answer":"The floor-standing enclosure measures 3560 mm wide × 1400 mm deep × 2820 mm high for standard efficiency. High-efficiency versions are 3860 mm wide × 1600 mm deep × 2820 mm high."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A14003333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A14003333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}