{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A14305555","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A14305555","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A14305555","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A14305555","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A14305555 AC drive, 1195 kW motor power, 1430 kVA apparent power, 2970-3630 V supply, 30-pulse rectifier, floor-standing enclosure.","salesMarkdown":"## Active production — what that means for procurement The ATV1200A14305555: Sourced through authorized distribution channels against your BOM quantity. ## Power rating and overload — sizing the drive to the load Rated for 1195 kW motor power with 1430 kVA apparent power. The 30-pulse diode rectifier bridge on a 2970-3630 V supply gives you the input harmonics profile a utility or plant distribution engineer expects for a drive this size — no external filter needed for most grid codes. Overload capability: 1.2 In for 60 s standard duty, 1.5 In for 3 s. High-overload profile pushes to 1.5 In for 60 s and 1.85 In for 3 s. That second profile is what you spec for a crusher, centrifuge, or any load that pulls hard on start or jogs. ## Physical footprint and construction — this is not a panel-mount drive Floor-standing enclosure with separate air flows for the transformer and power cells. Dimensions: 2820 mm tall, 3960 mm wide (high efficiency) or 3660 mm wide (standard efficiency), depth 1600 mm (high efficiency) or 1500 mm (standard efficiency). You need a concrete pad and overhead crane access for installation — this isn't a DIN-rail job. The drive ships as a composed assembly: 2 x plinth, phase-shifting transformer, medium-voltage arrestors, cooling fans, HMI, and 15 power cells. Forced convection cooling pulls 29900 m³/h (standard efficiency) or 33200 m³/h (high efficiency) — plan the room ventilation accordingly. ## I/O and control supply — what to wire in Four software-configurable analog inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ohm impedance) and two analog outputs of the same type. Discrete inputs: 6 standard, expandable to 10 optional. The control supply is 220 V AC at 3 kVA external; the cooling fan runs on a separate 380 V AC supply — don't share the control transformer with the fan circuit. Electrical isolation between power and control. Dielectric strength tested at 20 kV AC between earth and power terminals — that's the hipot number the commissioning engineer signs off on. ## Standards and compliance — what the CE mark covers CE marked. Complies with EN/IEC 60204-11 (machinery safety), EN/IEC 60529 (enclosure protection), EN/IEC 61800-3 (EMC for drive systems), EN/IEC 61800-4 (drive performance), and EN/IEC 61800-5-1 (electrical safety). The integrated EMC filter covers conducted emissions for the typical industrial environment. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. Prospective line short-circuit current rated at 31.5 kA for 150 ms — the upstream protection must coordinate with that withstand.","metaTitle":"Schneider Electric ATV1200A14305555 AC Drive, 1195 kW","metaDescription":"Schneider Electric ATV1200A14305555 Altivar 1200 AC drive. 1195 kW motor power, 1430 kVA, 2970-3630 V input. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1600 mm (high efficiency) 1500 mm (standard efficiency)","Width":"3960 mm (high efficiency) 3660 mm (standard efficiency)","title":"ATV1200A14305555","Height":"2820 mm standard efficiency 2820 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"30 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 5.5 kV - 1430 kVA","Line current":"150 A","Apparent power":"1430 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"1195 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 15 x power cells","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"29900 m3/h (standard efficiency) 33200 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP42 IP31","Network number of phases":"3 phases","Continuous output current":"150 A (standard overload) 120 A (high overload)","Maximum transient current":"180 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"5.5 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Sensorless flux vector control Closed-loop control with encoder Vector control with sensor, optional Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"48 kW (standard efficiency) 42 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A14305555/medium-voltage-variable-speed-drive-atv1200-5-5-kv-1430-kva/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for ATV1200A14305555?","answer":"The ATV1200A14305555 is sourced to order against your BOM quantity through authorized distribution. Current pricing and lead time are confirmed at quote time — submit an RFQ for your specific volume and delivery window."},{"question":"What is ATV1200A14305555's power rating?","answer":"The drive is rated for 1195 kW motor power with 1430 kVA apparent power, operating from a 2970-3630 V supply via a 30-pulse diode rectifier. Overload capability is 1.2 In for 60 s standard duty or 1.5 In for 60 s high duty."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A14305555","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A14305555 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}