{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A14504242","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A14504242","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A14504242","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A14504242","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A14504242 medium-voltage AC drive, 1212 kW motor power, 1450 kVA apparent power, 24-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Medium-voltage drive for large motor loads The Schneider Electric ATV1200A14504242 is an Altivar 1200 series medium-voltage AC drive rated for 1212 kW motor power with 1450 kVA apparent power, designed for large induction and synchronous motors in heavy industrial applications. It accepts a supply voltage of 2970...3630 V AC through a 24-pulse diode rectifier bridge, which reduces line-side harmonics below IEEE 519 thresholds without external filters. ## Overload profile and fault handling Standard overload capability is 1.2× rated current for 60 seconds and 1.5× for 3 seconds; high overload mode extends the 1.5× window to 60 seconds and allows 1.85× for 3 seconds — this matters for crushers, conveyors, and mills that see short-duration peak torque events. The drive withstands a prospective line short-circuit current of 31.5 kA for 150 ms, and dielectric strength between earth and power terminals is tested at 20 kV AC. Ground fault protection is integrated on the drive side, and the unit is pollution degree 2 rated per EN/IEC 61800-5-1. ## Physical footprint and cooling The drive ships in a floor-standing enclosure with separate air flows for power and control sections. Standard efficiency variant measures 1400 mm deep × 4060 mm wide × 2670 mm high; the high efficiency version is 1600 mm deep × 4360 mm wide at the same height. Forced convection cooling moves 16500 m³/h (standard) or 19900 m³/h (high efficiency) of air, with an 80 dB noise level — plan for hearing protection zones near the installation. Operating altitude range is 1000...2000 m with 0.6 % current derating per 100 m above 1000 m; the unit must be mounted vertically within ±10 degrees. ## Compliance and lifecycle The ATV1200A14504242 carries CE marking and conforms to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Lifecycle status is current production — quoted to order against the BOM quantity through independent distribution channels.","metaTitle":"Schneider ATV1200A14504242 AC Drive, 1212 kW, 1450 kVA","metaDescription":"Schneider Electric ATV1200A14504242 medium-voltage VFD, 1212 kW motor power, 1450 kVA apparent power, 24-pulse rectifier, CE marked. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1600 mm (high efficiency)","Width":"4060 mm (standard efficiency) 4360 mm (high efficiency)","title":"ATV1200A14504242","Height":"2670 mm high efficiency 2670 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"24 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 4.16 kV - 1450 kVA","Line current":"200 A","Apparent power":"1450 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"1212 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 12 x power cells","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"16500 m3/h (standard efficiency) 19900 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP42 IP31","Network number of phases":"3 phases","Continuous output current":"200 A (standard overload) 160 A (high overload)","Maximum transient current":"240 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"4.16 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"48 kW (standard efficiency) 42 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A14504242/medium-voltage-variable-speed-drive-atv1200-4-16-kv-1450-kva/"},"ai":{"faq":[{"question":"What overload ratings does this drive support?","answer":"Standard overload: 1.2 In for 60 s and 1.5 In for 3 s. High overload: 1.5 In for 60 s and 1.85 In for 3 s. The high overload profile suits applications with frequent peak torque demands."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A14504242","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A14504242 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}