{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A147501010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A147501010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A147501010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A147501010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A147501010, medium-voltage AC drive (VFD), 12331 kW motor power, 14750 kVA apparent power, 48-pulse input, 2970-3630 VAC supply, floor-standing enclosure.","salesMarkdown":"## Medium-voltage drive for large asynchronous motors The Schneider Electric ATV1200A147501010 is a medium-voltage AC drive from the Altivar 1200 range, rated for 12331 kW motor power at a 14750 kVA apparent power rating, supplied from a 2970–3630 VAC line. It uses a 48-pulse diode rectifier bridge input, which inherently reduces line-side current harmonics far below the levels a standard 6- or 12-pulse drive would produce — a practical advantage when feeding from a weak grid or trying to avoid a dedicated harmonic filter. The unit is assembled in a floor-standing enclosure with separate airflows for the power cells and control section, and forced-convection cooling moves 160000 m³/h of air at standard efficiency. ## Overload profile and application fit Overload capability is defined for two duty profiles: standard overload allows 1.2× rated current for 60 seconds or 1.5× for 3 seconds; high overload pushes to 1.5× for 60 seconds or 1.85× for 3 seconds. This split lets an integrator match the drive to either a constant-torque load (conveyor, extruder) needing the standard profile or a high-breakaway-torque application (crusher, mill) where the 1.85× short-term peak handles the start-up inertia without oversizing the drive frame. Output voltage tracks the supply voltage, so the motor terminal voltage is whatever the incoming line delivers — no step-up or boost inside the drive. The drive ships as a complete assembly including the phase-shifting transformer, 24 power cells, cooling fans, medium-voltage arrestors, and the human-machine interface — the product composition is a matched system, not a standalone inverter.","metaTitle":"Schneider ATV1200A147501010 AC Drive, 12331 kW, 14750 kVA","metaDescription":"Schneider Electric Altivar 1200 medium-voltage drive, 12331 kW motor power, 14750 kVA apparent power. 48-pulse diode rectifier, 2970-3630 V supply.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"15680 mm (standard efficiency)","title":"ATV1200A147501010","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"48 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 10 kV - 14750 kVA","Line current":"850 A","Apparent power":"14750 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"12331 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"28 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 24 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"160000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP42 IP31","Network number of phases":"3 phases","Continuous output current":"850 A (standard overload) 680 A (high overload)","Maximum transient current":"1020 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"10 kV +/- 10 % 6.6 kV","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder Sensorless flux vector control Vector control with sensor, optional","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"432 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A147501010/medium-voltage-variable-speed-drive-atv1200-10-kv-14750-kva/"},"ai":{"faq":[{"question":"What compliance standards does this drive meet?","answer":"It carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The pollution degree rating is 2, and overvoltage category is II per the same standard."},{"question":"What is the physical footprint of the ATV1200A147501010?","answer":"The floor-standing enclosure measures 3040 mm height by 15680 mm width by 1700 mm depth at standard efficiency. These dimensions matter for floor loading and crane access during installation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A147501010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A147501010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}