{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A15506666","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A15506666","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A15506666","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A15506666","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A15506666 medium-voltage AC drive, 1296 kW motor power, 1550 kVA, 2970...3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## 1296 kW medium-voltage drive with 36-pulse rectifier The ATV1200A15506666 is a medium-voltage AC drive from the Altivar 1200 series, rated for 1296 kW motor power at 1550 kVA apparent power. Supply voltage range is 2970...3630 V — this is a medium-voltage drive, not a 480 V class unit, so the input transformer and switchgear upstream need to match that voltage class. The 36-pulse diode rectifier front end means the drive presents very low line current harmonics — typically below 5 % THD without an external filter. For a 1550 kVA load, that saves the cost of a dedicated harmonic filter cabinet and simplifies IEEE 519 compliance at the point of common coupling. The drive is assembled in a floor-standing enclosure with separate air flows for the power cells and the control section. The product composition includes 18 power cells, a phase-shifting transformer, medium-voltage arrestors, cooling fans, and an HMI. This is a complete drive cabinet — not a modular drive that fits into a customer panel. Two efficiency variants exist: standard efficiency requires 16500 m³/h of cooling air, while the high-efficiency variant needs 19800 m³/h. The physical footprint differs between the two — standard efficiency width is 3960 mm, high efficiency width is 4260 mm; depth is 1500 mm for standard, 1600 mm for high efficiency; height is 2670 mm for both. The enclosure colour is grey RAL 7032. Forced convection cooling with a noise level of 80 dB — this is not a quiet drive; ear protection is needed in the equipment room. The operating position is vertical ±10 degrees. ## Overload profiles and protection The drive offers two overload profiles: standard overload handles 1.2× In for 60 s and 1.5× In for 3 s; high overload handles 1.5× In for 60 s and 1.85× In for 3 s. The high overload profile is the one to specify if the motor drives a high-inertia load like a centrifuge or a crusher that needs extended torque during acceleration. Ground fault protection is built into the drive. Dielectric strength between earth and power terminals is 20 kV AC. Prospective line short-circuit current rating is 31.5 kA for 150 ms — this sets the SCCR requirement for the upstream switchgear. ## I/O and control supply The drive has 4 software-configurable analogue inputs (0...20 mA / 4...20 mA, 24 V max, 250 Ohm impedance) and 1 analogue output of the same type. Discrete inputs: 6 standard, expandable to 10. Control supply is 220 V AC at 3 kVA, with an optional 220 V AC/DC supply. The cooling fan has its own internal 380 V AC supply, with an optional external 380 V AC supply available. Electrical isolation between power and control circuits is standard for this voltage class. CE marked. Complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1. Overvoltage category II per the same standard. Operating altitude 1000...2000 m with 0.6 % current derating per 100 m above 1000 m. Lifecycle stage is marked as current production. The ATV1200A15506666 is sourced to order against the BOM quantity through independent distribution channels.","metaTitle":"Schneider ATV1200A15506666 AC Drive, 1296 kW, 1550 kVA","metaDescription":"Schneider Electric ATV1200A15506666 medium-voltage VFD, 1296 kW motor power, 1550 kVA apparent power, 36-pulse rectifier. CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"1600 mm (high efficiency) 1500 mm (standard efficiency)","Width":"3960 mm (standard efficiency) 4260 mm (high efficiency)","Height":"2670 mm high efficiency 2670 mm standard efficiency","Current":"135 A","IP Rating":"IP41 / IP42 / IP31","Input Type":"36 pulse diode rectifier bridge","Coil Voltage":"220 V","Product Status":"Active","Protection Type":"Ground fault protection: drive","Pollution Degree":"Pollution degree 2","Temp Storage Max":"60 °C","Temp Storage Min":"-10 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"50 °C","Temp Operating Min":"0 °C","Temperature Storage":"-10...60 °C","Ambient Air Temperature Operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A15506666/medium-voltage-variable-speed-drive-atv1200-6-6-kv-1550-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV1200A15506666/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A15506666","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A15506666 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}