{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A16105555","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A16105555","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A16105555","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A16105555","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A16105555 medium-voltage variable speed drive, 1346 kW motor power, 1610 kVA apparent power, 30-pulse diode rectifier, 2970-3630 V supply, floor-standing enclosure.","salesMarkdown":"## 1346 kW motor rating — what it means for your load The ATV1200A16105555 is rated for 1346 kW motor power at an apparent power of 1610 kVA. That puts it squarely in the medium-voltage drive class for large synchronous and asynchronous motors — think mainline conveyors, mine hoists, large pumps, and compressors where the motor nameplate sits north of 1 MW. The 30-pulse diode rectifier input means the drive draws line current at 200 A with a harmonic profile that typically meets IEEE 519 without additional filtering — a real advantage when the plant's power-quality engineer is watching the THD at the PCC. ## Supply voltage and input topology — the medium-voltage reality Supply voltage limits are 2970 to 3630 V — this is a 3.3 kV-class drive, not a 4160 V or 6.6 kV unit. The output voltage is <= the supply voltage, so the motor winding insulation and the transformer taps need to match the incoming bus, not the other way around. The prospective line short-circuit current is 31.5 kA for 150 ms. That number governs the upstream breaker or fuse coordination — the drive's input section is designed to ride through that fault level without catastrophic failure, but the protection devices upstream need to be set to clear within that window. ## Physical footprint and enclosure — plan the floor space now This drive ships as a floor-standing enclosure with separate air flows for power and control sections. The standard-efficiency variant measures 4360 mm wide by 1500 mm deep; the high-efficiency version is 4660 mm wide by 1600 mm deep. Both stand 2670 mm tall. That is a substantial footprint — plan for a dedicated drive room with overhead crane access for the transformer and cell replacement. Cooling airflow is 19800 m³/h for standard efficiency, 23100 m³/h for high efficiency. The noise level at full load is 80 dB — hearing protection zones and acoustic treatment need to be in the room layout from the start. ## Overload capability and duty cycle The overload profiles are defined for both standard and high overload applications: 1.2× In for 60 s or 1.5× In for 3 s under standard overload; 1.5× In for 60 s or 1.85× In for 3 s under high overload. That means the drive can handle a 185 % current spike for three seconds — enough to break a stuck conveyor or clear a jam without tripping, but the duty cycle needs to respect the thermal recovery time between events. ## Compliance and standards — what the CE mark covers The drive carries CE marking and is designed to EN/IEC 60204-11 (safety of machinery), EN/IEC 60529 (ingress protection), EN/IEC 61800-3 (EMC for adjustable-speed drives), EN/IEC 61800-4 (drive system requirements), and EN/IEC 61800-5-1 (electrical, thermal, and energy safety). Pollution degree 2 per EN/IEC 61800-5-1 means it is intended for a clean, climate-controlled electrical room — not a dusty mill floor. Dielectric strength is 20 kV AC between earth and power terminals. That is the withstand voltage for the insulation system — relevant for the commissioning hipot test and for verifying that the isolation between the medium-voltage power section and the control electronics is intact. ## Sourcing and lifecycle — active production, quoted to order The product composition includes the phase-shifting transformer, 15 power cells, cooling fans, HMI, and medium-voltage arrestors — it arrives as a complete drive system, not a bare chassis that needs a separate line-up of components.","metaTitle":"Schneider Electric ATV1200A16105555 Altivar 1200, 1346 kW","metaDescription":"Schneider Electric ATV1200A16105555 Altivar 1200 medium-voltage drive. 1346 kW motor power, 1610 kVA apparent power, 30-pulse input, CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"1600 mm (high efficiency) 1500 mm (standard efficiency)","Width":"4360 mm (standard efficiency) 4660 mm (high efficiency)","Height":"2670 mm high efficiency 2670 mm standard efficiency","Current":"200 A","IP Rating":"IP42 / IP31 / IP41","Input Type":"30 pulse diode rectifier bridge","Coil Voltage":"220 V","Product Status":"Active","Protection Type":"Ground fault protection: drive","Pollution Degree":"Pollution degree 2","Temp Storage Max":"60 °C","Temp Storage Min":"-10 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"50 °C","Temp Operating Min":"0 °C","Temperature Storage":"-10...60 °C","Ambient Air Temperature Operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A16105555/medium-voltage-variable-speed-drive-atv1200-5-5-kv-1610-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV1200A16105555/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A16105555","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A16105555 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}