{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A17301010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A17301010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A17301010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A17301010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A17301010 AC drive, 1446 kW motor power, 1730 kVA, 2970-3630 V input, 48-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## 1446 kW motor power, 1730 kVA apparent power The Schneider Electric ATV1200A17301010 is an Altivar 1200 medium-voltage AC drive rated for 1446 kW motor power and 1730 kVA apparent power, with a supply voltage range of 2970 to 3630 V. This is a floor-standing drive with a 48-pulse diode rectifier input, designed for asynchronous motor control in high-power applications like pumps, fans, and compressors. The drive's overload profile is specified at 1.2 In for 60 s and 1.5 In for 3 s under standard overload, and 1.5 In for 60 s and 1.85 In for 3 s under high overload — this defines the thermal headroom for starting and transient loads without tripping. ## Physical footprint and enclosure integration The drive measures 1700 mm deep, 4260 mm wide, and 2670 mm high in its standard-efficiency configuration, housed in a floor-standing enclosure with separate air flows for power and control sections. Forced convection cooling moves 23100 m³/h of air, with an 80 dB noise level — plan for acoustic isolation in occupied areas. The enclosure is grey (RAL 7032) and the operating position is vertical ±10 degrees. The electrical connection uses M10 screw-type bars with a clamping capacity of 6 x 40 mm² per phase, entry from top or bottom. ## Standards compliance and isolation The ATV1200A17301010 carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Electrical isolation between power and control circuits is provided, with a dielectric strength of 28 kV AC between earth and power terminals. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. The drive includes integrated EMC filtering and a prospective short-circuit current rating of 31.5 kA for 150 ms.","metaTitle":"Schneider Electric ATV1200A17301010 AC Drive, 1446 kW","metaDescription":"Schneider Electric ATV1200A17301010 Altivar 1200 AC drive, 1446 kW motor power, 1730 kVA apparent power, 2970-3630 V input. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"4260 mm (standard efficiency)","Height":"2670 mm standard efficiency","Current":"100 A","IP Rating":"IP42 / IP41 / IP31","Input Type":"48 pulse diode rectifier bridge","Coil Voltage":"220 V","Product Status":"Active","Protection Type":"Ground fault protection: drive","Pollution Degree":"Pollution degree 2","Temp Storage Max":"60 °C","Temp Storage Min":"-10 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"50 °C","Temp Operating Min":"0 °C","Temperature Storage":"-10...60 °C","Ambient Air Temperature Operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A17301010/medium-voltage-variable-speed-drive-atv1200-10-kv-1730-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV1200A17301010/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A17301010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A17301010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}