{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A19105555","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A19105555","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A19105555","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A19105555","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A19105555 medium-voltage AC drive, 1597 kW motor power, 1910 kVA apparent power, 30-pulse diode rectifier input, 2970...3630 V supply, floor-standing enclosure.","salesMarkdown":"## Active production — what that means for procurement The ATV1200A19105555: For volume BOM commitments, this drive is quoted to order against the line-item quantity. ## 1597 kW at medium voltage — the load it handles Rated for 1597 kW motor power with 1910 kVA apparent power, this drive serves synchronous or asynchronous motors in the medium-voltage class. The 30-pulse diode rectifier bridge input reduces line-side harmonics compared to 6- or 12-pulse topologies — relevant for sites with strict IEEE 519 compliance requirements. Supply voltage limits are 2970...3630 V, placing it in the 3.3 kV class. The output voltage is at or below the supply voltage, so motor winding insulation must be rated for the full DC bus potential. ## Overload profile and fault clearing Standard overload withstand is 1.2 In for 60 s and 1.5 In for 3 s; the high-overload profile pushes to 1.5 In for 60 s and 1.85 In for 3 s. This matters when sizing for applications with intermittent peak loads — a crusher or centrifuge that hits 150 % torque for a few seconds will trip a drive set to standard overload if the duration exceeds 3 s. Prospective line short-circuit current is 31.5 kA for 150 ms, and dielectric strength between earth and power terminals is 20 kV AC. Ground fault protection is built into the drive. These ratings define the upstream protection coordination — the supply transformer and feeder breaker must clear within that 150 ms window. ## Physical footprint and installation constraints Assembled in a floor-standing enclosure with separate air flows. Dimensions vary by efficiency variant: standard efficiency is 1500 mm deep × 4660 mm wide × 2670 mm high; high efficiency is 1700 mm deep × 4960 mm wide × 2670 mm high. The high-efficiency variant adds 200 mm depth and 300 mm width — enough to affect floor layout and cable entry planning. Cooling is forced convection moving 23100 m³/h of air — this is substantial airflow that must be ducted or room-vented. Noise level is 80 dB, which may require hearing protection in the drive room or acoustic enclosures in noise-sensitive areas. Operating altitude range is 1000...2000 m with current derating of 0.6 % per 100 m above 1000 m. Vibration resistance is 4.9 m/s² at 10...50 Hz. The operating position is vertical ±10 degrees. ## I/O complement and control supply Four software-configurable analogue inputs accept 0...20 mA or 4...20 mA, 24 V max, 250 Ohm impedance. Two analogue outputs are similarly configurable. Discrete inputs number 6 standard, expandable to 10 optional. Control supply is external at 220 V AC, 3 kVA. The cooling fan has its own internal supply at 380 V AC, with optional external supply at 380 V AC. Electrical isolation between power and control circuits is standard — no optocoupler or DC/DC converter needed for the control interface. CE marked. Conforms to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II per the same standard. The integrated EMC filter covers conducted emissions for the drive's rated environment. Relative humidity range is 0...90 % standard, 0...95 % optional. The product composition includes a phase-shifting transformer, medium voltage arrestors, cooling fans, a human-machine interface, and 15 power cells.","metaTitle":"Schneider ATV1200A19105555 AC Drive, 1597 kW, 1910 kVA","metaDescription":"Schneider Electric ATV1200A19105555 medium-voltage AC drive, 1597 kW motor power, 1910 kVA apparent power, 30-pulse input, CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1500 mm (standard efficiency) 1700 mm (high efficiency)","Width":"4660 mm (standard efficiency) 4960 mm (high efficiency)","title":"ATV1200A19105555","Height":"2670 mm high efficiency 2670 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"30 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 5.5 kV - 1910 kVA","Line current":"200 A","Apparent power":"1910 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"1597 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 15 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"23100 m3/h (high efficiency) 23100 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP31 IP41","Network number of phases":"3 phases","Continuous output current":"200 A (standard overload) 160 A (high overload)","Maximum transient current":"240 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"5.5 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Sensorless flux vector control Voltage/frequency ratio (V/f) Closed-loop control with encoder Vector control with sensor, optional","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"64 kW (standard efficiency) 56 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/uk/en/product/download-pdf/ATV1200A19105555?filename=Schneider+Electric_Altivar-1200_ATV1200A19105555.pdf', 'path_name': '346305efbd88916502d5a3236190cd9a.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/346305efbd88916502d5a3236190cd9a.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A19105555/medium-voltage-variable-speed-drive-atv1200-5-5-kv-1910-kva/"},"ai":{"faq":[{"question":"What is the motor power rating of ATV1200A19105555?","answer":"Rated motor power is 1597 kW with an apparent power of 1910 kVA. It drives both synchronous and asynchronous motors at medium voltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A19105555","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A19105555 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}