{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A20003333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A20003333","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A20003333","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A20003333","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A20003333 medium-voltage AC drive, 1672 kW motor power, 2970-3630 V supply, 18-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"The ATV1200A20003333 is a medium-voltage AC drive rated for 1672 kW motor power with a supply voltage range of 2970-3630 V AC. This places it squarely in the MV drive class for large induction or synchronous motors — think mainline conveyors, mine hoists, large pumps, or compressor trains where a 480 V low-voltage drive would require impractical current levels. The 18-pulse diode rectifier input topology delivers significantly lower line current harmonics than a standard 6-pulse drive, often eliminating the need for external harmonic filters in medium-voltage installations. Line current is 410 A with an apparent power rating of 2000 kVA. Overload capability follows a dual profile: 1.2 x In for 60 seconds (standard) or 1.5 x In for 3 seconds, with a high-overload variant offering 1.5 x In for 60 seconds and 1.85 x In for 3 seconds. This matters when sizing for applications with intermittent peak loads — the 60-second window at 1.5x covers most starting and short-term overload events without oversizing the drive. ## Floor-standing construction and cooling demands This drive ships as a floor-standing enclosure with separate airflows for the transformer and power cells. Physical footprint is substantial: 1500 mm depth (standard efficiency) or 1700 mm (high efficiency), 4560 mm or 4860 mm width respectively, and 2670 mm height. Plan the installation bay accordingly — this is not a wall-mount unit. Forced convection cooling moves 19800 m³/h (standard efficiency) or 23100 m³/h (high efficiency) of air. The noise level is 80 dB — ear protection zones around the drive are expected in operation. Operating position is vertical within ±10 degrees. The product composition includes a phase-shifting transformer, 9 power cells, medium-voltage arrestors, cooling fans, and a human-machine interface. Power connections use M10 screw-type terminals accepting up to 6 x 40 mm² cable per phase, with entry from bottom or top. ## Compliance, isolation, and fault handling CE marked and designed to EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (adjustable speed drives), and EN/IEC 61800-5-1 (electrical safety). Pollution degree 2 per the safety standard, overvoltage category II. Electrical isolation between power and control circuits is provided. Dielectric strength is 10 kV AC between earth and power terminals. The drive withstands a prospective line fault current of 31.5 kA for 150 ms — this sets the upstream protection coordination requirements. Ground fault protection is integrated into the drive. Altitude derating applies above 1000 m: 0.6 % current reduction per 100 m up to 2000 m. Relative humidity range is 0-90 % standard, 0-95 % optional. Vibration resistance is 4.9 m/s² at 10-50 Hz. ## Control interfaces and I/O Four software-configurable analogue inputs accept 0-20 mA or 4-20 mA signals at 24 V max with 250 Ohm impedance. Two analogue outputs are similarly configurable. Discrete inputs number 6 standard, expandable to 10 optional. External control supply is 220 V AC at 3 kVA; an optional 220 V AC/DC supply is available. The internal cooling fan supply runs at 380 V AC. An integrated EMC filter is included.","metaTitle":"Schneider ATV1200A20003333 AC Drive, 1672 kW, 2970-3630 V","metaDescription":"Schneider Electric ATV1200A20003333 medium-voltage AC drive, 1672 kW motor power, 2970-3630 V input. 18-pulse rectifier, CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1500 mm (standard efficiency) 1700 mm (high efficiency)","Width":"4560 mm (standard efficiency) 4860 mm (high efficiency)","title":"ATV1200A20003333","Height":"2670 mm high efficiency 2670 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"18 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 3.3 kV - 2000 kVA","Line current":"410 A","Apparent power":"2000 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"1672 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"10 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer 9 x power cells Medium voltage arrestors Cooling fans Human machine interface","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"19800 m3/h (standard efficiency) 23100 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP42 IP31","Network number of phases":"3 phases","Continuous output current":"350 A (standard overload) 280 A (high overload)","Maximum transient current":"420 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"3.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Sensorless flux vector control Voltage/frequency ratio (V/f) Closed-loop control with encoder Vector control with sensor, optional","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"67 kW (standard efficiency) 59 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A20003333?filename=Schneider+Electric_Altivar-1200_ATV1200A20003333.pdf', 'path_name': '284d29f5772701a28bce1986fbcc3403.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/284d29f5772701a28bce1986fbcc3403.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A20003333/medium-voltage-variable-speed-drive-atv1200-3-3-kv-2000-kva/"},"ai":{"faq":[{"question":"What is the ATV1200A20003333 used for?","answer":"This is a medium-voltage AC drive (Altivar 1200 series) rated for 1672 kW motor power at 2970-3630 V input. It is designed for large asynchronous or synchronous motors in applications like conveyors, pumps, compressors, and fans where a low-voltage drive would require excessive current."},{"question":"What compliance documentation comes with the ATV1200A20003333?","answer":"The drive is CE marked and complies with EN/IEC 61800-3 (EMC), EN/IEC 61800-4, and EN/IEC 61800-5-1 (electrical safety). Dielectric strength is 10 kV AC between earth and power terminals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A20003333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A20003333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}