{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A22906666","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A22906666","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A22906666","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A22906666","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A22906666 medium-voltage AC drive, 1914 kW motor power, 2290 kVA apparent power, 200 A line current, 36-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## What this drive is and what it powers The ATV1200A22906666 is a Schneider Electric Altivar 1200 medium-voltage AC drive rated for 1914 kW motor power with 2290 kVA apparent power and 200 A line current. It's built for asynchronous motor control in applications where a standard low-voltage drive won't cut the voltage — the supply limits are 2970...3630 V AC. The 36-pulse diode rectifier input stage means the drive draws line current with low harmonic distortion — no external harmonic filter needed for most utility interfaces. The integrated EMC filter handles the conducted emissions side. ## Overload capability and duty cycle Standard overload rating: 1.2 x In for 60 seconds, 1.5 x In for 3 seconds. High overload rating pushes to 1.5 x In for 60 seconds and 1.85 x In for 3 seconds. That's the difference between a pump/fan duty and a crusher/mill duty — the high-overload window handles the breakaway torque of a loaded conveyor or a centrifuge start. The prospective line short-circuit current rating is 31.5 kA for 150 ms — the drive's input section can ride through a bolted fault on the primary side without catastrophic failure, as long as the upstream protection clears within that window. ## Physical footprint and installation constraints This is a floor-standing cabinet, not a panel-mount drive. The enclosure dimensions: 2670 mm high, 5170 mm wide (standard efficiency) or 5470 mm wide (high efficiency), and 1700 mm deep (high efficiency) or 1600 mm deep (standard efficiency). The operating position is vertical ±10 degrees — no laying it on its side. The assembly includes two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, an HMI, and 18 power cells. Forced convection cooling moves 23100 m³/h of air — the room's HVAC needs to handle that heat rejection, and the noise level at 80 dB means ear protection near the cabinet. ## I/O complement and control wiring Four software-configurable analogue inputs (0...20 mA / 4...20 mA, 24 V max, 250 Ohm impedance) and one analogue output of the same type. Six discrete inputs standard, expandable to ten. The control supply is 220 V AC at 3 kVA — separate from the internal fan supply at 380 V AC. Electrical isolation between power and control circuits. ## Standards compliance and environmental limits CE marked. Designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. Dielectric strength tested at 20 kV AC between earth and power terminals. Operating altitude 1000...2000 m with current derating of 0.6 % per 100 m above 1000 m. Relative humidity 0...90 % standard, 0...95 % optional. Vibration resistance 4.9 m/s² at 10...50 Hz.","metaTitle":"Schneider ATV1200A22906666 Altivar 1200 VFD, 1914 kW","metaDescription":"Schneider Electric ATV1200A22906666 Altivar 1200 medium-voltage VFD. 1914 kW motor power, 2290 kVA apparent power, 200 A line current, 36-pulse diode rectifier.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (high efficiency) 1600 mm (standard efficiency)","Width":"5170 mm (standard efficiency) 5470 mm (high efficiency)","title":"ATV1200A22906666","Height":"2670 mm high efficiency 2670 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"36 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6.6 kV - 2290 kVA","Line current":"200 A","Apparent power":"2290 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"1914 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 18 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"23100 m3/h (high efficiency) 23100 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP41 IP31","Network number of phases":"3 phases","Continuous output current":"200 A (standard overload) 160 A (high overload)","Maximum transient current":"240 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6.6 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f) Sensorless flux vector control Vector control with sensor, optional","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"77 kW (standard efficiency) 67 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A22906666?filename=Schneider+Electric_Altivar-1200_ATV1200A22906666.pdf', 'path_name': '0008f19b79ccee702bd7d0cff3f0ac73.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/0008f19b79ccee702bd7d0cff3f0ac73.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A22906666/medium-voltage-variable-speed-drive-atv1200-6-6-kv-2290-kva/"},"ai":{"faq":[{"question":"What are the main electrical ratings of the ATV1200A22906666?","answer":"Motor power rating is 1914 kW, apparent power is 2290 kVA, and line current is 200 A. The input supply voltage range is 2970...3630 V AC through a 36-pulse diode rectifier. Output voltage is ≤ the supply voltage."},{"question":"What overload ratings does this drive support?","answer":"Standard overload: 1.2 x In for 60 s and 1.5 x In for 3 s. High overload: 1.5 x In for 60 s and 1.85 x In for 3 s. The high-overload profile suits heavy starting duty like conveyors or mills."},{"question":"What physical space does the ATV1200A22906666 require?","answer":"The floor-standing enclosure measures 2670 mm high, 5170 mm wide (standard efficiency) or 5470 mm wide (high efficiency), and 1700 mm deep (high efficiency) or 1600 mm deep (standard efficiency). Operating position is vertical ±10°."},{"question":"What compliance documentation does Schneider provide for this drive?","answer":"CE marking is standard. The drive complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2, overvoltage category II. Dielectric strength tested at 20 kV AC between earth and power terminals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A22906666","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A22906666 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}