{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A23401010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A23401010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A23401010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A23401010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A23401010 AC drive, 1956 kW motor power, 2340 kVA, 48-pulse diode rectifier, 2970-3630 V supply, floor-standing enclosure.","salesMarkdown":"## 48-pulse architecture for medium-voltage motor control The Schneider Electric ATV1200A23401010 is a medium-voltage AC drive from the Altivar 1200 family, rated for 1956 kW motor power with 2340 kVA apparent power. Its 48-pulse diode rectifier bridge input delivers low harmonic distortion without a separate filter — a key advantage for installations where IEEE 519 compliance is a constraint. Supply voltage range is 2970–3630 V, placing it in the medium-voltage class. The output voltage is limited to or below the supply voltage, so the motor nameplate voltage must align with the available line feed. ## Overload profile and thermal budget The overload withstand table defines two duty cycles: standard overload handles 1.2× In for 60 s and 1.5× In for 3 s; high overload pushes to 1.5× In for 60 s and 1.85× In for 3 s. This means the drive can ride through a crusher jam or a conveyor start without tripping, but the high-overload window is short — the 3 s limit at 1.85× In is a hard ceiling, not a suggestion. Forced convection cooling moves 23,100 m³/h through the floor-standing enclosure. The noise level is 80 dB — ear protection zones around the drive are expected in a typical installation. ## Architecture and internal composition The drive is built from 24 power cells fed by a phase-shifting transformer, plus medium-voltage arrestors, cooling fans, and a human-machine interface, all housed in a grey (RAL 7032) floor-standing enclosure with separate air flows for power and control sections. Electrical isolation between power and control means the control electronics can be safely referenced to earth while the power section runs at medium voltage — a standard safety separation for drives at this class. Dielectric strength is 28 kV AC between earth and power terminals, confirming the insulation coordination for a 3.3 kV class system. The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Prospective line short-circuit current withstand is 31.5 kA for 150 ms — this sets the upstream fuse or breaker requirement for coordination. The integrated EMC filter covers conducted emissions for the first environment per EN/IEC 61800-3. ## Sourcing and lifecycle position Sourced through independent distribution channels. For a drive of this scale — 1956 kW, floor-standing, 24 power cells — the quote should include the full enclosure dimensions (1700 mm depth, 5160 mm width, 2670 mm height) for site access planning.","metaTitle":"Schneider ATV1200A23401010 AC Drive, 1956 kW, 2340 kVA","metaDescription":"Schneider Electric ATV1200A23401010 AC drive, 1956 kW motor power, 2340 kVA apparent power, 48-pulse input, 2970-3630 V supply. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"5160 mm (standard efficiency)","title":"ATV1200A23401010","Height":"2670 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"48 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 10 kV - 2340 kVA","Line current":"135 A","Apparent power":"2340 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"1956 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"28 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 24 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"23100 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP31 IP41 IP42","Network number of phases":"3 phases","Continuous output current":"135 A (standard overload) 108 A (high overload)","Maximum transient current":"162 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"10 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Sensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"78 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A23401010?filename=Schneider+Electric_Altivar-1200_ATV1200A23401010.pdf', 'path_name': 'c65093c2c1b1fb0d05ee1d200ddffa51.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/c65093c2c1b1fb0d05ee1d200ddffa51.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A23401010/medium-voltage-variable-speed-drive-atv1200-10-kv-2340-kva/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for this drive?","answer":"The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The datasheet and declaration of conformity are available from Schneider Electric."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A23401010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A23401010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}