{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A24006363","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A24006363","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A24006363","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A24006363","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A24006363 medium-voltage variable speed drive, 1831 kW motor power, 2190 kVA apparent power, 36-pulse diode rectifier input, floor-standing enclosure.","salesMarkdown":"## 1831 kW medium-voltage drive with 36-pulse input The ATV1200A24006363 is a medium-voltage variable speed drive from the Altivar 1200 series, rated for 1831 kW motor power with 2190 kVA apparent power and a line current of 200 A. It uses a 36-pulse diode rectifier bridge input, which significantly reduces line-side harmonics compared to 6- or 12-pulse topologies — a key consideration when connecting to a weak grid or meeting IEEE 519 compliance without external filters. Supply voltage limits are 2970 to 3630 V, and the output voltage is equal to or less than the supply voltage — this is a direct-to-line drive, not a step-up configuration. The 36-pulse design requires a phase-shifting transformer, which is included as part of the product composition. ## Physical footprint and enclosure This drive ships in a floor-standing enclosure with separate air flows for the power section and control compartment. Dimensions depend on the efficiency variant: standard efficiency measures 5170 mm wide × 1600 mm deep × 2670 mm high; the high-efficiency version is wider at 5470 mm and deeper at 1700 mm, with the same height. The forced convection cooling system moves 23,100 m³/h of air — plan for adequate room ventilation and clearance around the enclosure intake and exhaust. ## Overload capability and motor compatibility The drive handles both standard and high overload profiles. Standard overload: 1.2 × In for 60 seconds or 1.5 × In for 3 seconds. High overload: 1.5 × In for 60 seconds or 1.85 × In for 3 seconds. This dual rating lets the same drive serve constant-torque applications (conveyors, extruders) on the high-overload curve and variable-torque loads (pumps, fans) on the standard curve — no need to oversize the drive for occasional peak demand. The ATV1200A24006363 is designed for both synchronous and asynchronous motors, with a speed range of 20 to 100 %. The integrated EMC filter and ground fault protection are built in, not optional add-ons. ## Compliance and standards coverage CE marked and designed to EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (harmonic), EN/IEC 61800-5-1 (safety), EN/IEC 60204-11 (machinery), and EN/IEC 60529 (enclosure protection). Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. Dielectric strength is 20 kV AC between earth and power terminals. Prospective line short-circuit current rating is 31.5 kA for 150 ms — the drive can ride through a bolted fault on the primary side without self-destructing. Lifecycle status is current production — this is an active catalogue item, not a discontinued or NRND part.","metaTitle":"Schneider Electric ATV1200A24006363 Altivar 1200, 1831 kW","metaDescription":"Schneider Electric ATV1200A24006363 medium-voltage drive, 1831 kW motor power, 2190 kVA apparent power, 36-pulse input. CE marked, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (high efficiency) 1600 mm (standard efficiency)","Width":"5170 mm (standard efficiency) 5470 mm (high efficiency)","title":"ATV1200A24006363","Height":"2670 mm high efficiency 2670 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"36 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6.3 kV - 2190 kVA","Line current":"200 A","Apparent power":"2190 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"1831 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 18 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"23100 m3/h (high efficiency) 23100 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP42 IP31","Network number of phases":"3 phases","Continuous output current":"200 A (standard overload) 160 A (high overload)","Maximum transient current":"240 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Vector control with sensor, optional Voltage/frequency ratio (V/f) Sensorless flux vector control Closed-loop control with encoder","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"73 kW (standard efficiency) 64 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A24006363?filename=Schneider+Electric_Altivar-1200_ATV1200A24006363.pdf', 'path_name': '3f72ae0acaccc4799ee1c7fe144f21ab.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/3f72ae0acaccc4799ee1c7fe144f21ab.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A24006363/medium-voltage-variable-speed-drive-atv1200-6-3-kv-2190-kva/"},"ai":{"faq":[{"question":"How can I get pricing and availability for the ATV1200A24006363?","answer":"The drive is sourced to order against your BOM quantity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A24006363","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A24006363 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}