{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A25006060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A25006060","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A25006060","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A25006060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A25006060 medium-voltage variable speed drive, 2090 kW motor power, 2970-3630 V supply, 30-pulse diode rectifier, floor-standing enclosure with separate air flows, CE marked.","salesMarkdown":"The ATV1200A25006060 is a Schneider Electric Altivar 1200 medium-voltage variable speed drive rated for 2090 kW motor power at a supply voltage of 2970 to 3630 V. That 2090 kW figure is the continuous motor output the drive can support under standard overload conditions — not a peak or short-time rating. The input stage uses a 30-pulse diode rectifier bridge, which means the harmonic distortion fed back to the line is significantly lower than a 6- or 12-pulse design — relevant if your facility has a utility-imposed harmonic limit or you're feeding from a weak grid. Overload capability is specified as 1.2 In for 60 seconds (standard overload) and 1.5 In for 3 seconds, with a high-overload profile at 1.5 In for 60 seconds and 1.85 In for 3 seconds. The 60-second window at 1.2× rated current covers most starting and load-transient scenarios without forcing a larger drive frame. ## Physical footprint and enclosure integration This drive ships in a floor-standing enclosure with separate air flows for the power section and control compartment. The standard-efficiency variant measures 4660 mm wide by 1600 mm deep by 2670 mm high; the high-efficiency variant is 4960 mm wide by 1700 mm deep at the same height. Forced convection cooling moves 23100 m³/h of air through the cabinet — that volume has to be accounted for in the room's HVAC design, especially if the drive sits in a confined electrical room with other heat sources. The enclosure colour is grey RAL 7032, and the operating position is vertical within ±10 degrees. Mounting orientation outside that window will affect the cooling airflow path and may require derating. ## Supply requirements and auxiliary power The main power supply range is 2970 to 3630 V, with a prospective line short-circuit current withstand of 31.5 kA for 150 ms. That fault rating tells you the drive's input bus can survive a bolted fault at the line terminals long enough for upstream protection to clear — coordination with the supply-side breaker is still required. Control power comes from an external 220 V AC, 3 kVA supply. The cooling fans draw from an internal 380 V AC supply, with an optional external 220 V AC/DC control supply and external 380 V AC fan supply listed as alternatives. The 3 kVA control transformer must be sized into the panel's auxiliary load budget. Line current at rated load is 280 A, with an apparent power of 2500 kVA. The power connection uses M10 bar-type screw terminals accepting 6 x 40 mm² conductors per phase, entry from the bottom or top. ## I/O complement and control interface The drive provides 4 software-configurable analogue inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ohm impedance) and 1 analogue output of the same type. Discrete inputs number 6 standard, expandable to 10 via an optional module. Electrical isolation is maintained between the power and control circuits — the dielectric strength between earth and power terminals is tested at 20 kV AC. This isolation rating is consistent with the EN/IEC 61800-5-1 standard for medium-voltage drives and supports direct connection to the motor without an intermediate isolation transformer in most configurations. ## Environmental limits and derating rules Operating altitude from 1000 to 2000 m requires a current derating of 0.6 % per 100 m above 1000 m. At 2000 m, that's a 6 % reduction in available output current — factor this into the motor sizing if the installation is at elevation. Relative humidity range is 0 to 90 % non-condensing, with an optional extension to 95 %. Pollution degree 2 per EN/IEC 61800-5-1 applies, meaning only non-conductive pollution is expected — the enclosure seal and filter maintenance schedule should reflect the actual site conditions. Vibration resistance is 4.9 m/s² over 10 to 50 Hz, and the noise level at full load is 80 dB. The 80 dB figure is the acoustic emission at the operator position — hearing protection may be required in the drive room depending on local noise exposure limits. ## Compliance and standards coverage CE marked and designed to EN/IEC 60204-11 (electrical equipment of machines — requirements for HV equipment), EN/IEC 60529 (enclosure protection), EN/IEC 61800-3 (EMC for adjustable-speed drives), EN/IEC 61800-4 (general requirements for LV and MV drives), and EN/IEC 61800-5-1 (electrical, thermal, and energy safety). An integrated EMC filter is included, and overvoltage category II per EN/IEC 61800-5-1 applies. The drive supports both synchronous and asynchronous motors per the product destination listing. ## Lifecycle status and sourcing posture The product composition includes 2 plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and 15 power cells. Each power cell is a modular building block — if a cell fails in service, the drive can continue at reduced capacity while the replacement cell is sourced. Sourced to order against the BOM quantity through independent industrial distribution.","metaTitle":"Schneider Electric ATV1200A25006060 Altivar 1200, 2090 kW","metaDescription":"Schneider Electric ATV1200A25006060 Altivar 1200 medium-voltage drive, 2090 kW motor power, 2970-3630 V supply, 30-pulse rectifier, floor-standing enclosure.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (high efficiency) 1600 mm (standard efficiency)","Width":"4660 mm (standard efficiency) 4960 mm (high efficiency)","title":"ATV1200A25006060","Height":"2670 mm high efficiency 2670 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"30 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6 kV - 2500 kVA","Line current":"280 A","Apparent power":"2500 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"2090 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 15 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"23100 m3/h (high efficiency) 23100 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP31 IP42 IP41","Network number of phases":"3 phases","Continuous output current":"241 A (standard overload) 192 A (high overload)","Maximum transient current":"289 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Sensorless flux vector control Vector control with sensor, optional Closed-loop control with encoder Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"84 kW (standard efficiency) 73 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A25006060?filename=Schneider+Electric_Altivar-1200_ATV1200A25006060.pdf', 'path_name': '4c9db919482fd3e4b45bbc88e7fc70a4.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/4c9db919482fd3e4b45bbc88e7fc70a4.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A25006060/medium-voltage-variable-speed-drive-atv1200-6-kv-2500-kva/"},"ai":{"faq":[{"question":"What motor types does ATV1200A25006060 support?","answer":"The drive is designed for both synchronous and asynchronous motors. The 2090 kW rating applies to continuous motor output under standard overload conditions."},{"question":"What compliance documentation does Schneider provide for ATV1200A25006060?","answer":"The drive is CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. An integrated EMC filter is included."},{"question":"How is ATV1200A25006060 quoted for volume purchases?","answer":"Sourced to order against the BOM quantity through independent industrial distribution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A25006060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A25006060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}