{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A35003333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A35003333","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A35003333","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A35003333","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A35003333 medium-voltage variable frequency drive, 2926 kW motor power, 3.3 kV supply, 18-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Medium-voltage drive, 2926 kW at 3.3 kV The ATV1200A35003333 is a Schneider Electric Altivar 1200 medium-voltage variable frequency drive rated for 2926 kW motor power with an apparent power of 3500 kVA. It accepts a supply voltage range of 2970...3630 V AC through an 18-pulse diode rectifier input stage, which inherently reduces line-side harmonics without an external filter. The 18-pulse topology means the drive draws line current at 720 A with a prospective short-circuit rating of 31.5 kA for 150 ms — the transformer and rectifier are built to handle fault-clearing coordination upstream. ## Overload profile and speed range Standard overload capability is 1.2 x rated current for 60 seconds and 1.5 x for 3 seconds; the high-overload profile steps to 1.5 x for 60 seconds and 1.85 x for 3 seconds. This gives the commissioning engineer a choice between a 120% continuous-duty machine and a 150% peak-duty machine depending on the load cycle — a crusher or centrifuge pulls the high-overload variant, a pump or fan runs standard. Speed range is 20...100%, meaning the drive can regulate down to 20% of base speed without a tachometer feedback — adequate for most variable-torque loads, but constant-torque applications below 20% need a speed encoder option. ## Physical footprint and cooling The drive ships as a floor-standing enclosure with separate air flows for the transformer and power cells. Dimensions are 1700 mm deep x 5870 mm wide x 2740 mm high — this is a room-sized asset, not a cabinet drop-in. Plan for a dedicated electrical room with a 60000 m³/h forced-convection cooling system and a noise level of 80 dB at full load. Operating altitude is 1000...2000 m with a 0.6% current derating per 100 m above 1000 m. At 2000 m the usable current drops to roughly 94% of the sea-level rating — factor this into the motor sizing if the installation is at elevation. CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3 (EMC), EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. Dielectric strength is 10 kV AC between earth and power terminals — the transformer and cell isolation are dimensioned for medium-voltage service. The integrated EMC filter and electrical isolation between power and control circuits mean the drive meets the conducted emission limits of EN/IEC 61800-3 without external add-ons for most second-environment (industrial) installations. Sourced to order against the BOM quantity through independent distribution.","metaTitle":"Schneider ATV1200A35003333 MV drive, 2926 kW, 3.3 kV","metaDescription":"Schneider Electric Altivar 1200 ATV1200A35003333 medium-voltage drive, 2926 kW motor power, 3.3 kV input, 18-pulse rectifier. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"5870 mm (standard efficiency)","title":"ATV1200A35003333","Height":"2740 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"18 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 3.3 kV - 3500 kVA","Line current":"720 A","Apparent power":"3500 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"2926 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"10 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer 9 x power cells Medium voltage arrestors Cooling fans Human machine interface","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"60000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP31 IP42 IP41","Network number of phases":"3 phases","Continuous output current":"612 A (standard overload) 490 A (high overload)","Maximum transient current":"735 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"3.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Vector control with sensor, optional Voltage/frequency ratio (V/f) Closed-loop control with encoder Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"111 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A35003333?filename=Schneider+Electric_Altivar-1200_ATV1200A35003333.pdf', 'path_name': '59ffddb1790491049cd60bb94738fa9e.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/59ffddb1790491049cd60bb94738fa9e.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A35003333/medium-voltage-variable-speed-drive-atv1200-3-3-kv-3500-kva/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A35003333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A35003333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}