{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A35006060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A35006060","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A35006060","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A35006060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A35006060 medium-voltage variable speed drive, 2926 kW motor power, 3.3 kV supply, 30-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## What this MV drive is and the load it handles The ATV1200A35006060 is a medium-voltage variable speed drive from the Altivar 1200 series, rated for 2926 kW motor power at a supply voltage of 2970 to 3630 V AC (3.3 kV class). It drives both synchronous and asynchronous motors — a single drive platform for pump, fan, compressor, or conveyor loads in the 2-3 MW range. The 30-pulse diode rectifier input stage keeps line current harmonics low enough to meet IEEE 519 without external filters — a key advantage for installations where the utility demands clean power at the point of common coupling. The integrated EMC filter covers conducted emissions per EN/IEC 61800-3. Line current draw is 410 A at the rated apparent power of 3500 kVA. Prospective short-circuit withstand is 31.5 kA for 150 ms — the drive's input section is built to ride through a fault without upstream breaker coordination headaches. ## Overload profile and protection envelope Overload capability is defined for two duty classes: standard overload allows 1.2× In for 60 s and 1.5× In for 3 s; high overload allows 1.5× In for 60 s and 1.85× In for 3 s. The 60-second window at 1.5× In in high-overload mode is the spec to check if the application has a crusher or centrifuge start cycle that pulls heavy current through the ramp. Ground fault protection is integral to the drive. Dielectric strength is 20 kV AC between earth and power terminals, and isolation between power and control circuits is electrical — no optocoupler drift to track over temperature. Pollution degree 2 per EN/IEC 61800-5-1 and overvoltage category II define the drive's installation environment: it expects a clean, controlled electrical room, not a dusty substation floor. Operating altitude derating starts at 1000 m, 0.6 % per 100 m up to 2000 m — factor that into the site survey before the plinth is poured. ## Physical footprint and cooling demand The drive ships in a floor-standing enclosure measuring 6070 mm wide by 1700 mm deep by 2670 mm high. The enclosure colour is grey RAL 7032. Cooling is forced convection with separate air flows for power and control sections, moving 29700 m³/h of air — the room HVAC must handle that rejection, not just the drive's own fans. Acoustic noise is 80 dB — ear protection zone signage is mandatory near the enclosure. The operating position is vertical ±10°, and vibration resistance is 4.9 m/s² at 10 to 50 Hz. Product composition includes 15 power cells, a phase-shifting transformer, medium-voltage arrestors, cooling fans, and a human-machine interface. Power connections are bar-type screw terminals M10, accepting 6 × 40 mm² cable per phase, entry from top or bottom. ## Control I/O and auxiliary supply options The control section offers 4 software-configurable analogue inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ω impedance) and 1 analogue output of the same type. Discrete inputs are 6 standard, expandable to 10. Control power requires an external 220 V AC supply at 3 kVA. The cooling fan circuit needs a separate 380 V AC feed — both can be supplied as external options. This split-supply architecture means the control cabinet must provide two independent feeds, not a single transformer tap. Speed range is 20 to 100 %. Relative humidity tolerance is 0 to 90 % non-condensing, with an optional 95 % rating. ## Production status and sourcing posture Sourced to order against your BOM quantity through independent distribution channels. Compliance documentation includes CE marking and conformance to EN/IEC 60204-11, 60529, 61800-3, 61800-4, and 61800-5-1. The drive meets the relevant machinery directive and EMC standards for industrial environments.","metaTitle":"ATV1200A35006060 Altivar 1200 MV Drive, 2926 kW, 3.3 kV","metaDescription":"Schneider Electric ATV1200A35006060 medium-voltage drive, 2926 kW, 3.3 kV, 30-pulse input, current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (high efficiency) 1700 mm (standard efficiency)","Width":"6070 mm (high efficiency) 6070 mm (standard efficiency)","title":"ATV1200A35006060","Height":"2670 mm high efficiency 2670 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"30 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6 kV - 3500 kVA","Line current":"410 A","Apparent power":"3500 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"2926 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 15 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"29700 m3/h (standard efficiency) 29700 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP31 IP41","Network number of phases":"3 phases","Continuous output current":"337 A (standard overload) 269 A (high overload)","Maximum transient current":"404 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"117 kW (standard efficiency) 102 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A35006060?filename=Schneider+Electric_Altivar-1200_ATV1200A35006060.pdf', 'path_name': '5ec5b24dbfeb38432dd31ac0b86a58e7.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/5ec5b24dbfeb38432dd31ac0b86a58e7.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A35006060/medium-voltage-variable-speed-drive-atv1200-6-kv-3500-kva/"},"ai":{"faq":[{"question":"What is ATV1200A35006060's overload capability?","answer":"Standard overload: 1.2× rated current for 60 s and 1.5× for 3 s. High overload: 1.5× for 60 s and 1.85× for 3 s. The 60-second window at 1.5× In in high-overload mode is the spec to check for heavy start cycles like crushers or centrifuges."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A35006060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A35006060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}