{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A35304242","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A35304242","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A35304242","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A35304242","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A35304242 medium voltage variable speed drive, 2951 kW motor power, 2970-3630 V supply, 24-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## 2951 kW MV drive for synchronous and asynchronous motors The Schneider Electric ATV1200A35304242 is an Altivar 1200 medium voltage drive rated for 2951 kW motor power on a 2970-3630 V supply. It drives both synchronous and asynchronous motors — the 24-pulse diode rectifier front end keeps line-side harmonics low enough to skip a separate filter in most installations, and the apparent power rating of 3530 kVA gives the headroom the motor needs during acceleration. ## Overload profiles and fault current coordination Two overload profiles are available: standard overload handles 1.2× In for 60 s and 1.5× In for 3 s; high overload steps up to 1.5× In for 60 s and 1.85× In for 3 s. The prospective line short-circuit current is 31.5 kA for 150 ms — this figure feeds the selective coordination study for the upstream MV switchgear. Pollution degree 2 per EN/IEC 61800-5-1 and overvoltage category II define the insulation coordination envelope. ## Floor-standing cabinet with separate air flows The drive ships in a floor-standing enclosure with separate air flows for the power section and control compartment. Composition includes the phase-shifting transformer, 12 power cells, cooling fans, MV arrestors, and the HMI. Physical footprint: 5470 mm wide, 1700 mm deep, 2820 mm high — plan the substation floor layout around these dimensions, with clearance for the bottom or top cable entry on the M10 bar terminals. ## Auxiliary supplies and cooling demand Control power requires an external 220 V AC supply at 3 kVA; the cooling fan draws its own 380 V AC feed — both can be supplied as optional external feeds. Forced convection moves 43200 m³/h of cooling air at 80 dB noise level — the ventilation duct and acoustic treatment need to match this flow. Operating altitude above 1000 m requires derating the current by 0.6 % per 100 m up to 2000 m. ## I/O complement and control wiring Four software-configurable analogue inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ω impedance) and one analogue output of the same type. Six discrete inputs standard, expandable to ten. Electrical isolation between power and control circuits means the 24 VDC control loop stays referenced to the PLC ground, not the MV bus. Dielectric strength is 20 kV AC between earth and power terminals. ## Compliance and standards coverage CE marked. Standards applied: EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, EN/IEC 61800-5-1. The integrated EMC filter covers conducted emissions for the drive system. Ground fault protection is built into the drive. ## Active production — sourcing posture Lifecycle stage is current production.","metaTitle":"Schneider Electric ATV1200A35304242 Medium Voltage Drive","metaDescription":"Altivar 1200 medium voltage drive, 2951 kW motor power, 2970-3630 V supply. 24-pulse diode rectifier. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (high efficiency) 1700 mm (standard efficiency)","Width":"5470 mm (high efficiency) 5470 mm (standard efficiency)","title":"ATV1200A35304242","Height":"2820 mm standard efficiency 2820 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"24 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 4.16 kV - 3530 kVA","Line current":"490 A","Apparent power":"3530 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"2951 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 12 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"43200 m3/h (standard efficiency) 43200 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP41 IP31","Network number of phases":"3 phases","Continuous output current":"490 A (standard overload) 392 A (high overload)","Maximum transient current":"588 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"4.16 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder Vector control with sensor, optional Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"115 kW (standard efficiency) 103 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/uk/en/product/download-pdf/ATV1200A35304242?filename=Schneider+Electric_Altivar-1200_ATV1200A35304242.pdf', 'path_name': '9190193c9f03b4171fdb6bf91e322080.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/9190193c9f03b4171fdb6bf91e322080.pdf', 'status': 1}","sourceUrl":"https://www.se.com/uk/en/product/ATV1200A35304242/medium-voltage-variable-speed-drive-atv1200-4-16-kv-3530-kva/"},"ai":{"faq":[{"question":"What motor types does this drive support?","answer":"The ATV1200A35304242 is designed for both synchronous and asynchronous motors. The 24-pulse diode rectifier front end provides low line-side harmonics suitable for MV motor applications."},{"question":"What compliance documentation is available for ATV1200A35304242?","answer":"The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. An integrated EMC filter covers conducted emissions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A35304242","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A35304242 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}