{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A37803333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A37803333","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A37803333","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A37803333","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A37803333 medium-voltage AC drive, 3160 kW motor power, 2970-3630 V supply, 18-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Medium-voltage drive for 3 MW motor loads The Schneider Electric ATV1200A37803333 is an Altivar 1200 series medium-voltage AC drive rated for 3160 kW motor power with a supply voltage range of 2970 to 3630 V. This is a floor-standing cabinet assembly measuring 5870 mm wide by 2740 mm tall by 1700 mm deep — it occupies a dedicated substation room, not a panel. The 18-pulse diode rectifier bridge input topology inherently mitigates line harmonics, reducing the need for external filters. The drive handles both asynchronous and synchronous motors, with a speed range of 20 to 100% and 720 A line current at full load. Apparent power rating is 3780 kVA. ## Overload profiles and duty cycle planning Four distinct overload profiles are available: 1.2× rated current for 60 seconds (standard), 1.5× for 3 seconds (standard), 1.5× for 60 seconds (high overload), and 1.85× for 3 seconds (high overload). Match the profile to your application's peak torque demand — a crusher or centrifuge start may need the high-overload 60-second window. The prospective line short-circuit current rating is 31.5 kA for 150 ms, which sets the upstream protection coordination requirement. Ground fault protection is integrated into the drive. Dielectric strength between earth and power terminals is 10 kV AC, with electrical isolation between power and control circuits. ## System architecture and cooling demands The drive comprises 2 plinths, a phase-shifting transformer, 9 power cells, medium-voltage arrestors, cooling fans, and a human-machine interface. Forced convection cooling moves 60000 m³/h of air — the installation room must have corresponding ventilation or ducting. Noise level is 80 dB, so ear protection zones and acoustic treatment may be needed near the drive. Operating altitude is limited to 1000 m with derating of 0.6% per 100 m up to 2000 m. The control section requires an external 220 V AC supply at 3 kVA; the cooling fan runs on 380 V AC. An optional external supply for control at 220 V AC/DC is available, as is an optional external fan supply at 380 V AC. ## Control interface and field wiring The drive provides 4 software-configurable analogue inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ohm impedance), 1 analogue output (same current ranges), and 6 discrete inputs expandable to 10. The I/O is suitable for basic speed reference, feedback, and start/stop commands. Power connection uses bar-type M10 screw terminals accepting 6 x 40 mm² cable per phase, with entry from the bottom or top. Output voltage is at or below the supply voltage. An integrated EMC filter is standard. Compliance standards include EN/IEC 61800-3 (EMC), EN/IEC 61800-4, EN/IEC 61800-5-1, EN/IEC 60204-11, and EN/IEC 60529. CE marking is applied. ## Environmental limits for installation planning Relative humidity range is 0 to 90% non-condensing, optionally 0 to 95%. Operating position must be vertical within ±10 degrees. Vibration resistance is 4.9 m/s² over 10 to 50 Hz. The enclosure colour is grey (RAL 7032). Assembly style is floor-standing with separate air flows for power and control sections.","metaTitle":"Schneider ATV1200A37803333 AC Drive VFD, 3160 kW","metaDescription":"Schneider Electric ATV1200A37803333 Altivar 1200 medium-voltage drive, 3160 kW motor power, 18-pulse rectifier, floor-standing enclosure. CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"5870 mm (standard efficiency)","title":"ATV1200A37803333","Height":"2740 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"18 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 3.3 kV - 3780 kVA","Line current":"720 A","Apparent power":"3780 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"3160 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"10 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer 9 x power cells Medium voltage arrestors Cooling fans Human machine interface","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"60000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP31 IP42","Network number of phases":"3 phases","Continuous output current":"661 A (standard overload) 529 A (high overload)","Maximum transient current":"794 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"3.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"120 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A37803333?filename=Schneider+Electric_Altivar-1200_ATV1200A37803333.pdf', 'path_name': '77681766099e891a103137fa9e4ef4b3.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/77681766099e891a103137fa9e4ef4b3.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A37803333/medium-voltage-variable-speed-drive-atv1200-3-3-kv-3780-kva/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for ATV1200A37803333?","answer":"The drive carries CE marking and complies with EN/IEC 61800-3 (EMC), EN/IEC 61800-4, EN/IEC 61800-5-1, EN/IEC 60204-11, and EN/IEC 60529. Dielectric strength is 10 kV AC between earth and power terminals, with electrical isolation between power and control circuits."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A37803333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A37803333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}