{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A38101010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A38101010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A38101010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A38101010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A38101010, medium-voltage variable speed drive, 3185 kW motor power, 3810 kVA apparent power, 48-pulse diode rectifier, 2970-3630 V supply, floor-standing enclosure.","salesMarkdown":"## Floor-standing MV drive — 1500 mm deep, 6870 mm wide, 2670 mm tall The ATV1200A38101010 is a medium-voltage variable speed drive from the Altivar 1200 series, built for asynchronous motor control up to 3185 kW. It occupies a floor-standing enclosure measuring 1500 mm deep by 6870 mm wide by 2670 mm tall — this is not a panel-mount unit; it needs a dedicated equipment room or outdoor shelter with crane access for installation. The drive uses a 48-pulse diode rectifier front end, which keeps input harmonics low enough to meet IEEE 519 without an external filter in most installations. The internal phase-shifting transformer and 24 power cells deliver the stepped voltage waveform that drives the motor. ## Power stage and overload — 3810 kVA, 220 A line current, 1.2 In for 60 s Rated apparent power is 3810 kVA with a line current of 220 A at the 2970-3630 V supply range. The output voltage tracks the supply voltage — there is no step-up or step-down inside the drive. Overload capability is defined in two profiles: standard overload handles 1.2× rated current for 60 seconds and 1.5× for 3 seconds; high overload handles 1.5× for 60 seconds and 1.85× for 3 seconds. This lets the drive start high-inertia loads or ride through short-duration overload events without tripping. The drive withstands a prospective line short-circuit current of 31.5 kA for 150 ms, and the dielectric strength between earth and power terminals is 28 kV AC — both figures confirm the insulation coordination for direct connection to medium-voltage distribution. ## Cooling, noise, and environmental limits Cooling is forced convection with separate air flows for the power cells and the transformer — the volume of cooling air is 26,400 m³/h at standard efficiency. The acoustic noise level is 80 dB, which matters for personnel exposure in the equipment room. Operating altitude is 1000 to 2000 m with a current derating of 0.6 % per 100 m above 1000 m. Relative humidity range is 0 to 90 % standard, 0 to 95 % optional. Pollution degree 2 per EN/IEC 61800-5-1 applies — the enclosure is rated for a controlled environment, not open outdoor exposure. The drive must be installed vertically within ±10 degrees. Vibration resistance is 4.9 m/s² at 10-50 Hz, which covers normal floor vibration in industrial buildings but not seismic zones without additional anchoring. ## Control I/O and auxiliary supplies The control section requires an external 220 V AC supply at 3 kVA; an optional 220 V AC/DC supply is available. The cooling fan runs from a separate 380 V AC supply — this means two independent auxiliary feeds must be run to the drive cabinet. Discrete inputs: 6 standard, expandable to 10 optional. Analogue inputs: 4, software-configurable for 0-20 mA or 4-20 mA, 24 V max, 250 Ω impedance. Analogue outputs: 1, also software-configurable for 0-20 mA or 4-20 mA DC. Electrical connection is via bar-type screw terminals M10, clamping capacity 6 × 40 mm² for the line supply (/R, L2/S, L3/T), with entry from the bottom or top of the enclosure. CE marked. Standards applied include EN/IEC 60204-11 (electrical equipment of machines), EN/IEC 60529 (enclosure protection), EN/IEC 61800-3 (EMC for drive systems), EN/IEC 61800-4 (drive specifications), and EN/IEC 61800-5-1 (electrical, thermal, and energy safety). The EMC filter is integrated. Production status is current — the drive is in active manufacture.","metaTitle":"Schneider Electric ATV1200A38101010 Altivar 1200, 3185 kW","metaDescription":"Schneider Electric ATV1200A38101010 Altivar 1200 medium-voltage drive, 3185 kW motor power, 3810 kVA apparent power, 48-pulse rectifier, CE marked, current","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"1500 mm (standard efficiency)","Width":"6870 mm (standard efficiency)","Height":"2670 mm standard efficiency","Current":"220 A","IP Rating":"IP41 / IP31 / IP42","Input Type":"48 pulse diode rectifier bridge","Coil Voltage":"220 V","Product Status":"Active","Protection Type":"Ground fault protection: drive","Pollution Degree":"Pollution degree 2","Temp Storage Max":"60 °C","Temp Storage Min":"-10 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"50 °C","Temp Operating Min":"0 °C","Temperature Storage":"-10...60 °C","Ambient Air Temperature Operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A38101010/medium-voltage-variable-speed-drive-atv1200-10-kv-3810-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV1200A38101010/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A38101010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A38101010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}