{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A41203333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A41203333","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A41203333","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A41203333","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A41203333 medium-voltage AC drive, 3444 kW motor power, 2970-3630 VAC supply, 18-pulse diode rectifier input, floor-standing enclosure.","salesMarkdown":"## What the ATV1200A41203333 is and what it handles The Schneider Electric ATV1200A41203333 is an Altivar 1200 series medium-voltage AC drive rated for 3444 kW motor power, designed to run both asynchronous and synchronous motors from a 2970...3630 V supply. It draws 720 A line current and delivers 4120 kVA apparent power, with an 18-pulse diode rectifier front end that reduces line harmonics compared to a 6- or 12-pulse topology. ## Physical scale and installation constraints This is a large, floor-standing drive: 2740 mm high, 5870 mm wide, and 1700 mm deep in its standard-efficiency configuration, with separate air flows for the power section and control compartment. The enclosure is grey (RAL 7032) and must be installed vertically within ±10°; operating altitude above 1000 m requires derating the output current by 0.6 % per 100 m up to 2000 m. Forced-convection cooling moves 60000 m³/h of air at standard efficiency — plan the room's ventilation capacity around that airflow, not just the drive footprint. ## Overload capability and protection The drive offers two overload profiles: standard overload handles 1.2× In for 60 s or 1.5× In for 3 s; high overload handles 1.5× In for 60 s or 1.85× In for 3 s. Match the profile to the load duty cycle — a crusher or centrifuge starting into a loaded condition needs the high-overload setting. Built-in ground-fault protection covers the drive output, and the prospective line short-circuit current rating is 31.5 kA for 150 ms — the upstream protection must coordinate within that window. Dielectric strength is tested at 10 kV AC between earth and power terminals, and electrical isolation between power and control circuits is standard. ## Control wiring and I/O complement The drive includes 4 software-configurable analogue inputs (0...20 mA / 4...20 mA, 250 Ω impedance, 24 V max) and 1 analogue output of the same type, plus 6 discrete inputs expandable to 10 with an optional module. Control power comes from an external 220 V AC supply (3 kVA) or an optional 220 V AC/DC source; the internal cooling fan runs on 380 V AC, also available as an external option. ## Standards, compliance, and lifecycle CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II.","metaTitle":"Schneider Electric ATV1200A41203333 AC Drive, 3444 kW","metaDescription":"Schneider Electric ATV1200A41203333 Altivar 1200 medium-voltage drive, 3444 kW at 2970-3630 VAC. 18-pulse input, floor-standing enclosure. CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"5870 mm (standard efficiency)","title":"ATV1200A41203333","Height":"2740 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"18 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 3.3 kV - 4120 kVA","Line current":"720 A","Apparent power":"4120 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"3444 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"10 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer 9 x power cells Medium voltage arrestors Cooling fans Human machine interface","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"60000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP31 IP42 IP41","Network number of phases":"3 phases","Continuous output current":"720 A (standard overload) 576 A (high overload)","Maximum transient current":"864 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"3.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Vector control with sensor, optional Closed-loop control with encoder Voltage/frequency ratio (V/f) Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"127 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A41203333?filename=Schneider+Electric_Altivar-1200_ATV1200A41203333.pdf', 'path_name': 'b14a66704e058b8a516309f07eae67d8.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/b14a66704e058b8a516309f07eae67d8.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A41203333/medium-voltage-variable-speed-drive-atv1200-3-3-kv-4120-kva/"},"ai":{"faq":[{"question":"What motor types does this drive support?","answer":"It is designed for both asynchronous (induction) and synchronous motors, covering the majority of medium-voltage motor applications in pumps, fans, conveyors, compressors, and mills."},{"question":"What compliance documentation is available for the ATV1200A41203333?","answer":"The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. An integrated EMC filter is standard."},{"question":"Where can I buy the ATV1200A41203333 and how is it quoted?","answer":"This part is sourced through independent industrial distribution channels."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A41203333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A41203333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}