{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A42406363","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A42406363","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A42406363","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A42406363","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A42406363 medium-voltage AC drive, 3143 kW motor power, 3760 kVA apparent power, 36-pulse rectifier, floor-standing enclosure.","salesMarkdown":"## 3143 kW motor power — what that means for a medium-voltage drive installation The ATV1200A42406363 is an Altivar 1200 medium-voltage AC drive rated for 3143 kW motor power with 3760 kVA apparent power at the input. This is not a panel-mount VFD you bolt to a wall — it ships as a floor-standing enclosure with separate air flows, measuring 6670 mm wide by 2670 mm (standard efficiency) or 2970 mm (high efficiency) tall, 1700 mm deep. The 36-pulse diode rectifier bridge draws 410 A line current from a 2970…3630 V supply, which means the upstream transformer and switchgear must be sized for that voltage class and fault duty — the prospective line Isc is 31.5 kA for 150 ms. ## Overload profiles and protection coordination The overload withstand capability is defined for two duty classes: standard overload allows 1.2× In for 60 s and 1.5× In for 3 s; high overload allows 1.5× In for 60 s and 1.85× In for 3 s. This directly governs the motor protection settings — if the driven load is a high-inertia fan or centrifuge, the high-overload profile gives you the headroom to accelerate through the breakaway torque without tripping on overcurrent. Ground fault protection is integral to the drive, so an external ground-fault relay on the output is redundant unless the installation standard specifically requires it. ## System composition and cooling infrastructure The drive comprises 2 plinths, a phase-shifting transformer, medium voltage arrestors, cooling fans, an HMI, and 18 power cells. Forced convection cooling moves 33000 m³/h of air — that volume must be accounted for in the room HVAC design; the noise level at full fan speed is 80 dB, so hearing protection zones around the drive are expected. The control supply is 220 V AC at 3 kVA, with an optional external supply for the cooling fan at 380 V AC. Dielectric strength between earth and power terminals is 20 kV AC, confirming the insulation coordination for a 3.3 kV class system. ## Standards compliance and lifecycle status The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The lifecycle stage is listed as current — meaning the manufacturer continues to support this order code for new installations.","metaTitle":"Schneider ATV1200A42406363 Altivar 1200 VFD, 3143 kW","metaDescription":"Schneider Electric ATV1200A42406363 Altivar 1200 medium-voltage VFD. 3143 kW motor power, 3760 kVA apparent power, 36-pulse rectifier.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (high efficiency) 1700 mm (standard efficiency)","Width":"6670 mm (standard efficiency) 6670 mm (high efficiency)","title":"ATV1200A42406363","Height":"2670 mm standard efficiency 2970 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"36 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6.3 kV - 3760 kVA","Line current":"410 A","Apparent power":"3760 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"3143 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 18 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"33000 m3/h (standard efficiency) 33000 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP31 IP41","Network number of phases":"3 phases","Continuous output current":"345 A (standard overload) 276 A (high overload)","Maximum transient current":"414 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Closed-loop control with encoder Sensorless flux vector control Vector control with sensor, optional Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"126 kW (standard efficiency) 110 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A42406363?filename=Schneider+Electric_Altivar-1200_ATV1200A42406363.pdf', 'path_name': '8daac3f45a96b07ca6e69a6737faeb35.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/8daac3f45a96b07ca6e69a6737faeb35.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A42406363/medium-voltage-variable-speed-drive-atv1200-6-3-kv-3760-kva/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A42406363","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A42406363 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}