{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A42606060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A42606060","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A42606060","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A42606060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A42606060 medium-voltage variable speed drive, 3561 kW motor power, 4260 kVA apparent power, 2970-3630 V supply, 30-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Medium-voltage drive for 3.5 MW motor loads The ATV1200A42606060 is a Schneider Electric Altivar 1200 medium-voltage variable speed drive rated for 3561 kW motor power at 4260 kVA apparent power, with a supply voltage range of 2970 to 3630 V. This is a large-format drive — the floor-standing enclosure measures 6070 mm wide by 1700 mm deep by 2740 mm high in standard efficiency configuration, or 6370 mm wide by 1800 mm deep by 3040 mm high for the high efficiency variant. The input stage uses a 30-pulse diode rectifier bridge, which inherently cancels the 5th, 7th, 11th, 13th, 17th, and 19th harmonics — meeting IEEE 519 without external filters for most installations. An integrated EMC filter is included. The 3561 kW motor power rating at 4260 kVA apparent power tells you this drive handles a 3.3 kV induction or synchronous motor in the 3.5 MW class — typical for large pumps, compressors, conveyors, or mill drives in mining, cement, oil & gas, and water/wastewater. The 410 A line current at the 2970-3630 V supply gives the full-load input draw. Overload capability is defined per the drive's duty: 1.2× rated current for 60 seconds (standard overload) or 1.5× for 60 seconds (high overload), with short-duration peaks of 1.5× for 3 s (standard) and 1.85× for 3 s (high). This matches the IEC 61800-4 drive profile for heavy industrial loads that need starting torque or intermittent overloads. The 30-pulse rectifier topology means the drive draws near-sinusoidal line current — the 24-pulse equivalent already meets IEEE 519 at the point of common coupling for most sites, and the 30-pulse configuration adds margin. This avoids the cost and footprint of external harmonic filters. ## Physical integration and cooling This is a floor-standing enclosure with separate air flows for the power section and control compartment — the forced-convection cooling moves 46,500 m³/h of air through the cabinet. The operating position is vertical within ±10 degrees. The drive composition includes 15 power cells, a phase-shifting transformer, medium-voltage arrestors, cooling fans, and a human-machine interface. Electrical connection is via M10 bar-type terminals accepting 6 × 40 mm² conductors per phase, with cable entry from the top or bottom. Operating altitude is 1000 to 2000 m with 0.6% current derating per 100 m above 1000 m. Ambient relative humidity range is 0-90% (0-95% optional). Pollution degree 2 per EN/IEC 61800-5-1 applies — suitable for typical industrial electrical rooms with non-conductive pollution. ## Control I/O and compliance The drive offers 4 software-configurable analogue inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ω impedance) and 1 analogue output of the same type. Discrete inputs number 6 standard, expandable to 10. External control supply is 220 V AC at 3 kVA, with an optional 220 V AC/DC supply; the cooling fan runs on a separate 380 V AC supply. Electrical isolation between power and control circuits is provided. Dielectric strength is tested at 20 kV AC between earth and power terminals. The drive is CE marked and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Sourced through authorized distribution channels. No direct pin-compatible alternative exists within the Altivar 1200 family — the order code encodes the specific power rating, supply voltage, and enclosure configuration.","metaTitle":"Schneider ATV1200A42606060 Altivar 1200, 3561 kW, 4260 kVA","metaDescription":"Schneider Electric ATV1200A42606060 medium-voltage drive, 3561 kW motor power, 4260 kVA apparent power, 2970-3630 V supply. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency) 1800 mm (high efficiency)","Width":"6370 mm (high efficiency) 6070 mm (standard efficiency)","title":"ATV1200A42606060","Height":"2740 mm standard efficiency 3040 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"30 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6 kV - 4260 kVA","Line current":"410 A","Apparent power":"4260 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"3561 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 15 x power cells","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"46500 m3/h (standard efficiency) 46500 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP41 IP31","Network number of phases":"3 phases","Continuous output current":"410 A (standard overload) 328 A (high overload)","Maximum transient current":"492 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Voltage/frequency ratio (V/f) Sensorless flux vector control Closed-loop control with encoder Vector control with sensor, optional","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"142 kW (standard efficiency) 125 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A42606060?filename=Schneider+Electric_Altivar-1200_ATV1200A42606060.pdf', 'path_name': '3eeb7e85a8ede780f3661d2b5e480279.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/3eeb7e85a8ede780f3661d2b5e480279.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A42606060/medium-voltage-variable-speed-drive-atv1200-6-kv-4260-kva/"},"ai":{"faq":[{"question":"How do I get pricing and availability for ATV1200A42606060?","answer":"This drive is sourced to order against the BOM through authorized distribution."},{"question":"What compliance documentation does the ATV1200A42606060 carry?","answer":"The drive is CE marked and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Electrical isolation between power and control is provided, with 20 kV AC dielectric strength between earth and power terminals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A42606060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A42606060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}