{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A4305555","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A4305555","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A4305555","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A4305555","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A4305555 medium-voltage variable speed drive, 430 kVA, 359 kW, 2970–3630 V supply, 30-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"The ATV1200A4305555 is a medium-voltage variable speed drive from the Altivar 1200 family, rated for 430 kVA apparent power and 359 kW motor output. That power class targets large synchronous or asynchronous motors — think high-inertia loads like mine conveyors, mill drives, or large pumps where the starting torque and speed range (20…100%) need a drive that can handle sustained overload. Supply voltage limits are 2970…3630 V AC, fed through a 30-pulse diode rectifier bridge — the high pulse count cuts line-side harmonics well below IEEE 519 thresholds without external filters. The integrated EMC filter further simplifies panel compliance. ## Overload profile and duty cycle Two overload profiles are available: standard overload handles 1.2× In for 60 s and 1.5× In for 3 s; high overload pushes to 1.5× In for 60 s and 1.85× In for 3 s. That means the drive can ride through short-duration peak torque demands — a crusher jam or a cold-start high-viscosity pump — without tripping, as long as the duty cycle stays within those time limits. The drive is built as a floor-standing enclosure with separate air flows for power and control sections, keeping heat away from the electronics. Forced-convection cooling moves 16,600 m³/h (standard efficiency) or 19,900 m³/h (high efficiency) of air, so the installation site needs adequate ventilation clearance — the 80 dB noise level means ear protection near the unit during operation. ## I/O complement and control supply Six discrete inputs (expandable to 10) and four software-configurable analog inputs (0…20 mA / 4…20 mA, 24 V max, 250 Ω impedance) give the commissioning engineer enough channels for basic speed reference, start/stop, and fault reset without an extra I/O module. Two analog outputs mirror the same current range for retransmission to a PLC or remote meter. Control power comes from an external 220 V AC, 3 kVA supply; the cooling fans run off a separate 380 V AC feed. This split means the control electronics stay alive even if the main power is off — useful for diagnostics or pre-charge sequencing. An optional 220 V AC/DC control supply is also listed. ## Physical footprint and site preparation The enclosure dimensions vary with efficiency grade: standard efficiency measures 1400 mm deep × 2860 mm wide × 2590 mm high; high efficiency adds depth to 1500 mm, width to 3160 mm, and height to 2740 mm. That is a large footprint — plan for a dedicated equipment room with a reinforced floor and overhead lifting points for the transformer and power cells. Electrical connection is via M10 screw-type bars, accepting up to 6 × 40 mm² cable per phase, entry from top or bottom. The prospective short-circuit current rating is 31.5 kA for 150 ms, so upstream protection must coordinate within that window. CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3 (EMC), EN/IEC 61800-4, and EN/IEC 61800-5-1 (safety). Dielectric strength between earth and power terminals is 20 kV AC — a strong margin for medium-voltage isolation.","metaTitle":"Schneider Electric ATV1200A4305555 Altivar 1200, 430 kVA","metaDescription":"Active production medium-voltage drive, 430 kVA apparent power, 359 kW motor power, 30-pulse input, 2970–3630 V supply. CE marked, EN/IEC 61800 series.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"2860 mm (standard efficiency) 3160 mm (high efficiency)","Height":"2590 mm standard efficiency 2740 mm high efficiency","Current":"65 A","IP Rating":"IP31 / IP42 / IP41","Input Type":"30 pulse diode rectifier bridge","Coil Voltage":"220 V","Product Status":"Active","Protection Type":"Ground fault protection: drive","Pollution Degree":"Pollution degree 2","Temp Storage Max":"60 °C","Temp Storage Min":"-10 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"50 °C","Temp Operating Min":"0 °C","Temperature Storage":"-10...60 °C","Ambient Air Temperature Operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV1200A4305555/medium-voltage-variable-speed-drive-atv1200-5-5-kv-430-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV1200A4305555/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A4305555","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A4305555 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}