{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A44401010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A44401010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A44401010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A44401010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A44401010 medium-voltage variable speed drive, 3712 kW motor power, 4440 kVA apparent power, 48-pulse diode rectifier, 2970-3630 V supply, floor-standing enclosure.","salesMarkdown":"## Medium-voltage drive for large asynchronous motor loads The ATV1200A44401010 is a Schneider Electric Altivar 1200 medium-voltage variable speed drive, rated for 3712 kW motor power with 4440 kVA apparent power at the input. This places it squarely in the heavy industrial segment — think mainline conveyor drives in mining, large centrifugal pumps in water transmission, or ID/FD fans in power generation. It accepts a supply voltage of 2970 to 3630 V AC and draws 280 A line current. The input stage uses a 48-pulse diode rectifier bridge, which inherently cancels lower-order harmonics without requiring an external harmonic filter — a major advantage when the facility's power quality limits are tight. ## Ratings that drive the installation decision The 48-pulse rectifier topology means the drive meets IEEE 519 harmonic limits at the point of common coupling for most installations without added line reactors or active filters. The 31.5 kA prospective short-circuit current rating for 150 ms tells the protection engineer what upstream breaker and cable ratings are needed. Overload capability is specified in two profiles: standard overload handles 1.2× rated current for 60 seconds and 1.5× for 3 seconds; high overload handles 1.5× for 60 seconds and 1.85× for 3 seconds. The high overload profile is the one to use for applications like crushers or extruders that need sustained torque beyond the motor's rated current. Dielectric strength is 28 kV AC between earth and power terminals — this is the insulation coordination figure that governs the clearance and creepage distances inside the cabinet, and it confirms the drive is designed for ungrounded or high-resistance-grounded medium-voltage systems. Operating altitude above 1000 m requires derating the output current by 0.6% per 100 m. At 2000 m that's a 6% reduction — factor this into the motor sizing if the drive sits at elevation. ## Physical footprint and enclosure integration This drive ships as a floor-standing enclosure measuring 1600 mm deep, 7170 mm wide, and 3040 mm high — it occupies roughly 11.5 m² of floor space. The enclosure has separate air flows for the power cells and the phase-shifting transformer, so the ventilation ducting in the substation must keep these airstreams segregated to avoid recirculating hot air. The product composition includes 24 power cells, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and two plinths. The 48-pulse rectifier is achieved by the transformer's phase-shifting windings feeding the 24 cells — each cell sees a fraction of the total voltage, which also limits fault energy. Cooling is forced convection moving 70000 m³/h of air — that's substantial airflow requiring louvered intake and exhaust openings in the room, not just a few wall grilles. The noise level is 80 dB, so ear protection zones around the drive are expected. ## Standards compliance and documentation The drive carries CE marking and complies with EN/IEC 60204-11 (electrical equipment of machines), EN/IEC 60529 (ingress protection), EN/IEC 61800-3 (EMC for adjustable-speed drives), EN/IEC 61800-4 (voltage-source drives), and EN/IEC 61800-5-1 (electrical, thermal, and energy safety). The integrated EMC filter covers conducted emissions per the second-environment (industrial) limits of EN/IEC 61800-3. For first-environment (residential) compliance, an external filter would be needed, but that is rarely a concern for a 3.7 MW drive. ## Sourcing and lifecycle position For a project at this power level, the procurement lead time is driven by the transformer winding schedule and the power cell assembly cycle. No direct pin-compatible substitute exists in the Altivar 1200 family — the order code encodes the specific power rating, voltage class, and enclosure configuration.","metaTitle":"ATV1200A44401010 Altivar 1200 MV Drive, 3712 kW, 4440 kVA","metaDescription":"Schneider Electric ATV1200A44401010 medium-voltage drive, 3712 kW motor power, 4440 kVA apparent power, 48-pulse rectifier, CE marked, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1600 mm (standard efficiency)","Width":"7170 mm (standard efficiency)","title":"ATV1200A44401010","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"48 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 10 kV - 4440 kVA","Line current":"280 A","Apparent power":"4440 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"3712 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"28 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 24 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"70000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP42 IP31","Network number of phases":"3 phases","Continuous output current":"256 A (standard overload) 205 A (high overload)","Maximum transient current":"308 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"10 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Sensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"148 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A44401010?filename=Schneider+Electric_Altivar-1200_ATV1200A44401010.pdf', 'path_name': 'aa3396d0a982ece5a04fef732d3636b8.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/aa3396d0a982ece5a04fef732d3636b8.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A44401010/medium-voltage-variable-speed-drive-atv1200-10-kv-4440-kva/"},"ai":{"faq":[{"question":"What is the motor power rating of ATV1200A44401010?","answer":"The drive is rated for 3712 kW motor power with 4440 kVA apparent power at the input."},{"question":"What supply voltage does ATV1200A44401010 require?","answer":"It accepts 2970 to 3630 V AC supply voltage, putting it in the medium-voltage class for 3.3 kV nominal systems."},{"question":"What compliance documentation does this drive carry?","answer":"CE marking and compliance with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. An integrated EMC filter is included for industrial environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A44401010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A44401010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}