{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A4703333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A4703333","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A4703333","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A4703333","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A4703333 medium-voltage variable speed drive, 470 kVA, 393 kW motor power, 18-pulse diode rectifier, 2970-3630 V input, floor-standing enclosure.","salesMarkdown":"## What this MV drive delivers at the motor shaft The ATV1200A4703333 is an Altivar 1200 medium-voltage drive rated for 470 kVA apparent power and 393 kW motor output — enough to handle a large pump, compressor, or conveyor in the 3 kV class. Input voltage range is 2970 to 3630 V, line current 100 A, fed through an 18-pulse diode rectifier bridge that reduces line-side harmonics below IEEE 519 thresholds without an external filter. An integrated EMC filter is standard, and the drive meets EN/IEC 61800-3 for conducted emissions in the intended industrial environment. ## Footprint, cooling, and panel planning This is a floor-standing enclosure, not a panel-mount module — standard-efficiency dimensions are 2460 mm wide × 2520 mm high × 1400 mm deep; high-efficiency variant stretches to 2760 × 2670 × 1500 mm. Cooling is forced convection with separate air flows for power and control sections; the standard-efficiency unit moves 9900 m³/h, the high-efficiency version 13200 m³/h — plan for ducting or room HVAC capacity. Ambient temperature range and humidity (0-90 % RH, 0-95 % optional) are per the spec table. ## Overload profile and input topology Standard overload: 1.2 × In for 60 s, 1.5 × In for 3 s. High overload: 1.5 × In for 60 s, 1.85 × In for 3 s. The prospective short-circuit current rating is 31.5 kA for 150 ms. The 18-pulse input means no external harmonic filter is required for most applications — the phase-shifting transformer inside the enclosure cancels the 5th and 7th harmonics at the primary side. Dielectric strength is 10 kV AC between earth and power terminals; isolation is electrical between power and control circuits, with pollution degree 2 per EN/IEC 61800-5-1. ## I/O complement and motor compatibility Four software-configurable analogue inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ω impedance) and one analogue output of the same type. Six discrete inputs standard, expandable to ten. The drive handles both synchronous and asynchronous motors — the product composition includes a phase-shifting transformer, nine power cells, MV arrestors, cooling fans, and an HMI. Speed range is 20 to 100 % of rated speed. Output voltage equals the supply voltage (no step-up/step-down inside the drive). Overvoltage category II per EN/IEC 61800-5-1. The enclosure is grey (RAL 7032). Vibration resistance is 4.9 m/s² at 10-50 Hz.","metaTitle":"Schneider Electric ATV1200A4703333 Altivar 1200 MV Drive","metaDescription":"Schneider Electric ATV1200A4703333 medium-voltage Altivar 1200 drive, 470 kVA apparent power, 393 kW motor rating, 18-pulse input, CE marked, current","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"2460 mm (standard efficiency) 2760 mm (high efficiency)","title":"ATV1200A4703333","Height":"2520 mm standard efficiency 2670 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"18 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 3.3 kV - 470 kVA","Line current":"100 A","Apparent power":"470 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"393 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"10 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer 9 x power cells Medium voltage arrestors Cooling fans Human machine interface","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"9900 m3/h (standard efficiency) 13200 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP31 IP42","Network number of phases":"3 phases","Continuous output current":"82 A (standard overload) 66 A (high overload)","Maximum transient current":"98 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"3.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Sensorless flux vector control Closed-loop control with encoder Vector control with sensor, optional Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"16 kW (standard efficiency) 14 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A4703333?filename=Schneider+Electric_Altivar-1200_ATV1200A4703333.pdf', 'path_name': '7db1a4b0bcca01092688632b0dd31b79.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/7db1a4b0bcca01092688632b0dd31b79.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A4703333/medium-voltage-variable-speed-drive-atv1200-3-3-kv-470-kva/"},"ai":{"faq":[{"question":"What are the key electrical ratings of the ATV1200A4703333?","answer":"Apparent power is 470 kVA, motor power 393 kW, line current 100 A, input voltage range 2970-3630 V. Overload capability is 1.2 In for 60 s (standard) or 1.5 In for 60 s (high overload)."},{"question":"What compliance documentation does the ATV1200A4703333 carry?","answer":"CE marked. Designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Dielectric strength is 10 kV AC between earth and power terminals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A4703333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A4703333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}