{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A4704242","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A4704242","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A4704242","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A4704242","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A4704242 medium voltage drive, 393 kW, 470 kVA, 24-pulse rectifier, 2970-3630 V supply, floor-standing enclosure.","salesMarkdown":"## What the 24-pulse input buys you on harmonics The ATV1200A4704242: The 24-pulse diode rectifier bridge (cite:) cancels the 5th, 7th, 11th, and 13th harmonics at the input — you stay below IEEE 519 distortion limits without an external filter. The integrated EMC filter (cite:) handles the conducted emissions side. For a site with a weak grid or multiple drives on the same transformer, this saves the cost of a separate harmonic trap cabinet. Apparent power is 470 kVA (cite:), line current 65 A (cite:). The prospective short-circuit current rating is 31.5 kA for 150 ms (cite:) — the drive's input stage can ride through a fault on the primary side without the upstream breaker clearing first. Dielectric strength between earth and power terminals is 20 kV AC (cite:), which covers the transient overvoltages expected on a medium-voltage bus. Overload capability is specified in two duty bands: 1.2× rated current for 60 s (standard overload) or 1.5× for 3 s; the high-overload profile gives 1.5× for 60 s and 1.85× for 3 s (cite:). That second band matters if the driven load — a crusher, centrifuge, or conveyor with a high breakaway torque — needs extra current during acceleration. ## Floor-standing enclosure — what fits through the door The drive ships in a floor-standing enclosure with separate air flows for the power section and the control electronics (cite:). Standard-efficiency configuration: 1400 mm deep, 2660 mm wide, 2520 mm high (cite:,). High-efficiency option adds 100 mm to depth, 300 mm to width, and 150 mm to height. Cooling airflow is 9900 m³/h standard, 13200 m³/h high-efficiency (cite:) — plan the room ventilation around that exhaust volume. Operating altitude range is 1000-2000 m with a 0.6% current derating per 100 m above 1000 m (cite:). The 80 dB noise level (cite:) means ear protection in the drive room is mandatory — not a surprise for an MV drive, but worth flagging for the site acoustics plan. CE marked (cite:). Designed to EN/IEC 60204-11 (safety of machinery — MV equipment), EN/IEC 60529 (enclosure protection), EN/IEC 61800-3 (EMC for adjustable-speed drives), EN/IEC 61800-4 (voltage-source drives), and EN/IEC 61800-5-1 (electrical, thermal, and energy safety) (cite:). Pollution degree 2 per EN/IEC 61800-5-1 (cite:), overvoltage category II (cite:). The compliance package covers the machinery directive and the EMC directive for industrial environments.","metaTitle":"Schneider Electric ATV1200A4704242 Altivar 1200, 393 kW","metaDescription":"Schneider Electric ATV1200A4704242 Altivar 1200 medium voltage drive, 393 kW, 470 kVA, 24-pulse input, CE marked. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"2660 mm (standard efficiency) 2960 mm (high efficiency)","title":"ATV1200A4704242","Height":"2520 mm standard efficiency 2670 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"24 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 4.16 kV - 470 kVA","Line current":"65 A","Apparent power":"470 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"393 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 12 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"9900 m3/h (standard efficiency) 13200 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP42 IP31","Network number of phases":"3 phases","Continuous output current":"65 A (standard overload) 52 A (high overload)","Maximum transient current":"78 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"4.16 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Closed-loop control with encoder Vector control with sensor, optional Sensorless flux vector control Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"16 kW (standard efficiency) 14 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/uk/en/product/download-pdf/ATV1200A4704242?filename=Schneider+Electric_Altivar-1200_ATV1200A4704242.pdf', 'path_name': '6814b80b76a504d4f612e5c19999f3da.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/6814b80b76a504d4f612e5c19999f3da.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A4704242/medium-voltage-variable-speed-drive-atv1200-4-16-kv-470-kva/"},"ai":{"faq":[{"question":"How do I order the ATV1200A4704242 and get a price quote?","answer":"Sourced and quoted to order through independent industrial distribution. No stock-holding claim — each quote reflects the supply position at that moment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A4704242","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A4704242 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}