{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A51006060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A51006060","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A51006060","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A51006060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A51006060, medium-voltage variable frequency drive, 4264 kW motor power, 2970-3630 V supply, 30-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## What this MV drive delivers at the shaft The ATV1200A51006060 is a medium-voltage Altivar 1200 drive rated for 4264 kW motor power at a supply voltage of 2970 to 3630 V. It drives both synchronous and asynchronous motors, making it a single-drive option for a range of large rotating loads — pumps, compressors, fans, conveyors — where the motor type may differ between plant sections. The 30-pulse diode rectifier input stage draws a line current of 490 A and presents an apparent power of 5100 kVA. The multi-pulse topology reduces line-side harmonics below IEEE 519 thresholds without an external filter — the integrated EMC filter handles the conducted emissions side. ## Overload profile and fault handling Overload capability is defined at two duty levels: standard overload handles 1.2× In for 60 s or 1.5× In for 3 s; high overload handles 1.5× In for 60 s or 1.85× In for 3 s. The 60 s window at 1.5× In in high overload covers most starting and load-impulse scenarios for medium-voltage motors — a crusher or centrifuge start that needs 150 % torque for 40 s stays inside the curve. Prospective line short-circuit current is rated at 31.5 kA for 150 ms — the drive's input section withstands this fault level without upstream fusing intervention, provided the supply transformer and cabling are coordinated for that let-through. Ground fault protection is integrated into the drive, not left to an external relay. Dielectric strength between earth and power terminals is 20 kV AC, consistent with the 3.3 kV class insulation system. Pollution degree 2 per EN/IEC 61800-5-1 means the drive is intended for a clean, climate-controlled electrical room — not a dusty or conductive environment. ## Physical footprint and cooling The drive ships in a floor-standing enclosure with separate air flows for the power cells and control section. Standard efficiency dimensions: 1700 mm deep × 6070 mm wide × 2820 mm high; high efficiency variant adds depth to 1800 mm and height to 3040 mm, with width expanding to 6370 mm. Forced convection cooling moves 70000 m³/h of air through the enclosure — this volume dictates the room ventilation design. The noise level at full cooling is 80 dB, which requires hearing protection within the equipment aisle during operation. Operating altitude up to 1000 m is full-rated; above that, derate current by 0.6 % per 100 m up to 2000 m. The drive must be mounted vertical within ±10° — a floor bolt-down on a level pad is the intended installation. ## Control wiring and I/O complement Four software-configurable analogue inputs accept 0-20 mA or 4-20 mA signals at 24 V max, 250 Ω impedance. Two analogue outputs mirror the same current ranges. Discrete inputs number six standard, expandable to ten with an option — enough for run/stop, speed select, and fault reset without an external I/O block. Control power requires an external 220 V AC supply at 3 kVA. The cooling fan runs from a separate 380 V AC supply — this isolation means the fan can stay on for post-run cooldown even when the control circuit is off. An optional 220 V AC/DC control supply is available for sites with DC control buses. Electrical connection at the line side uses M10 bar-type screw terminals with a clamping capacity of 6 × 40 mm² per phase. Entry can be from the bottom or top — a detail that matters when laying out cable trenches versus overhead trays. The drive carries CE marking and complies with EN/IEC 60204-11 (electrical equipment of machines), EN/IEC 60529 (enclosure protection), EN/IEC 61800-3 (EMC for adjustable-speed drives), EN/IEC 61800-4 (functional safety), and EN/IEC 61800-5-1 (electrical safety). These standards cover the full scope of a medium-voltage drive installation in an industrial environment. Electrical isolation between power and control circuits is maintained — a requirement for safe troubleshooting when the drive is powered but the motor is stopped. The enclosure is grey RAL 7032, the standard industrial cabinet colour across Schneider's MV drive range. Sourced through independent distribution channels. No stock-holding claim is made; each order is quoted individually.","metaTitle":"Schneider ATV1200A51006060 Altivar 1200, 4264 kW","metaDescription":"Schneider Electric Altivar 1200 ATV1200A51006060 medium-voltage drive, 4264 kW motor power, 2970-3630 V supply.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency) 1800 mm (high efficiency)","Width":"6370 mm (high efficiency) 6070 mm (standard efficiency)","title":"ATV1200A51006060","Height":"2820 mm standard efficiency 3040 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"30 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6 kV - 5100 kVA","Line current":"490 A","Apparent power":"5100 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"4264 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 15 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"70000 m3/h (standard efficiency) 70000 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP31 IP42 IP41","Network number of phases":"3 phases","Continuous output current":"490 A (standard overload) 392 A (high overload)","Maximum transient current":"588 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Closed-loop control with encoder Sensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"162 kW (standard efficiency) 149 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A51006060?filename=Schneider+Electric_Altivar-1200_ATV1200A51006060.pdf', 'path_name': '2e84e26db342f00ed14eedde70fdb1e3.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/2e84e26db342f00ed14eedde70fdb1e3.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A51006060/medium-voltage-variable-speed-drive-atv1200-6-kv-5100-kva/"},"ai":{"faq":[{"question":"What is the motor power rating of the ATV1200A51006060?","answer":"The drive is rated for 4264 kW motor power at a supply voltage of 2970 to 3630 V. It can drive both synchronous and asynchronous motors."},{"question":"What compliance documentation is available for the ATV1200A51006060?","answer":"The drive is CE marked and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Standard Schneider documentation includes the product manual, installation guide, and EMC declaration."},{"question":"How can I order the ATV1200A51006060 or check availability?","answer":"This drive is sourced to order through independent distribution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A51006060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A51006060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}