{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A5205555","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A5205555","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A5205555","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A5205555","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A5205555 medium-voltage AC drive, 435 kW, 3.3 kV, 30-pulse rectifier, floor-standing enclosure, CE.","salesMarkdown":"## 435 kW at 3.3 kV — medium-voltage drive for large asynchronous and synchronous motors The ATV1200A5205555 is a Schneider Electric Altivar 1200 medium-voltage AC drive rated for 435 kW motor power with a supply voltage range of 2970...3630 V. This puts it squarely in the medium-voltage drive class, designed for large induction and synchronous motors in heavy industrial applications like pumps, fans, compressors, and conveyors where a step-down transformer and low-voltage drive would add cost and floor space. The 30-pulse diode rectifier input stage delivers low harmonic distortion — typically below 5% THD without external filters — which means it meets IEEE 519 requirements for most installations without added line reactors or active front ends. For a 520 kVA apparent power draw, that harmonic performance saves the cost of a dedicated harmonic filter cabinet. The drive offers two overload profiles: standard overload at 1.2 In for 60 s or 1.5 In for 3 s, and high overload at 1.5 In for 60 s or 1.85 In for 3 s. The standard profile suits variable-torque loads like centrifugal pumps and fans where overload events are rare and brief. The high-overload profile handles constant-torque loads such as conveyors or extruders that need sustained starting torque or occasional overload capacity without tripping. The 65 A line current at 3.3 kV input gives a quick check for upstream breaker and cable sizing. Prospective line Isc withstand is 31.5 kA for 150 ms, so the input disconnecting means must be rated for that fault level — a standard 40 kA-rated vacuum contactor or breaker covers it with margin. ## Floor-standing enclosure with separate air flows — installation planning The drive ships in a floor-standing enclosure with separate air flows for the power section and control electronics. Forced convection cooling moves 16600 m³/h in the standard-efficiency configuration and 19900 m³/h in the high-efficiency version. That volume of warm exhaust air must be ducted out of the room or the HVAC system must handle the heat load — plan for a dedicated ventilation plenum above the drive. Physical footprint: 2860 mm wide by 1400 mm deep (standard efficiency) or 3160 mm wide by 1500 mm deep (high efficiency), with height at 2590 mm or 2740 mm respectively. That is a large cabinet — verify door swing clearance, overhead crane access for the transformer and cell modules, and floor loading capacity before the unit arrives on site. For installations above 2000 m, contact the factory for application engineering — the standard derating curve may not cover the full altitude range. ## Control wiring and auxiliary supplies Control power requires an external 220 V AC supply at 3 kVA. The cooling fan runs on a separate 380 V AC supply — either internal or external depending on the configuration. This split supply architecture means the control electronics stay live for diagnostics even when the main 3.3 kV input is disconnected, as long as the 220 V auxiliary is present. The drive provides 4 software-configurable analog inputs (0...20 mA / 4...20 mA, 24 V max, 250 Ohm impedance) and 2 analog outputs of the same type. Discrete inputs number 6 standard, expandable to 10 with an option. Electrical isolation between power and control circuits means the 24 V DC control loop can share a common with other PLC I/O without ground-loop issues — the dielectric strength between earth and power terminals is 20 kV AC. ## Compliance and standards coverage CE marked and designed to EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (adjustable speed drives), EN/IEC 61800-5-1 (electrical safety), EN/IEC 60204-11 (safety of machinery), and EN/IEC 60529 (enclosure protection). Pollution degree 2 per EN/IEC 61800-5-1 means the drive is rated for normal industrial environments with only non-conductive pollution — no conductive dust or moisture ingress expected. Overvoltage category II covers equipment connected to the building wiring at the distribution level. The drive includes integrated ground fault protection and an integrated EMC filter. Noise level is 80 dB — hearing protection required within the enclosure perimeter during operation. Vibration resistance is 4.9 m/s² at 10...50 Hz, adequate for most industrial floor installations but not for direct mounting on reciprocating machinery without isolation mounts.","metaTitle":"Schneider Electric ATV1200A5205555 AC Drive, 435 kW, 3.3 kV","metaDescription":"Schneider Electric ATV1200A5205555 medium-voltage AC drive, 435 kW, 3.3 kV input, 30-pulse rectifier, CE marked. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"2860 mm (standard efficiency) 3160 mm (high efficiency)","title":"ATV1200A5205555","Height":"2590 mm standard efficiency 2740 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"30 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 5.5 kV - 520 kVA","Line current":"65 A","Apparent power":"520 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"435 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 15 x power cells","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"16600 m3/h (standard efficiency) 19900 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP31 IP41","Network number of phases":"3 phases","Continuous output current":"55 A (standard overload) 44 A (high overload)","Maximum transient current":"66 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"5.5 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Vector control with sensor, optional Sensorless flux vector control Closed-loop control with encoder Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"17 kW (standard efficiency) 15 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A5205555?filename=Schneider+Electric_Altivar-1200_ATV1200A5205555.pdf', 'path_name': 'b5756893019ec55dddaf48a71bd10158.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/b5756893019ec55dddaf48a71bd10158.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A5205555/medium-voltage-variable-speed-drive-atv1200-5-5-kv-520-kva/"},"ai":{"faq":[{"question":"What is the ATV1200A5205555 used for?","answer":"This medium-voltage AC drive controls asynchronous (induction) and synchronous motors up to 435 kW at 3.3 kV input. Typical applications include large pumps, fans, compressors, conveyors, and other heavy industrial loads where a medium-voltage drive eliminates the step-down transformer and low-voltage drive combination."},{"question":"How is the ATV1200A5205555 quoted for volume purchases?","answer":"The drive is sourced through independent distribution and quoted to order against the BOM quantity. No stock-holding claim is made; each order is confirmed against the manufacturer's production schedule."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A5205555","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A5205555 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}