{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A5606666","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A5606666","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A5606666","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A5606666","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A5606666 medium-voltage AC drive, 468 kW motor power, 560 kVA apparent power, 2970…3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Medium-voltage drive for 468 kW asynchronous motor loads The Schneider Electric ATV1200A5606666 is an Altivar 1200 series medium-voltage AC drive rated for 468 kW motor power at 560 kVA apparent power, supplied from a 2970…3630 V line via a 36-pulse diode rectifier bridge. That multi-pulse input topology keeps line-side harmonics low enough to meet IEEE 519 without a separate filter in most installations — a real advantage when the site's utility imposes strict THD limits. The drive is built for asynchronous (induction) motors and ships in a floor-standing enclosure with separate air flows for the power section and control compartment. The standard-efficiency variant measures 3060 mm wide × 2520 mm high × 1400 mm deep; the high-efficiency variant is slightly larger at 3360 mm wide × 2670 mm high × 1500 mm deep. Either way, the footprint demands a dedicated equipment room with a reinforced floor and a ventilation plan that moves 13,200–16,500 m³/h of cooling air. ## Overload profile and fault-current rating The overload withstand is specified for both standard and high-overload duty cycles: 1.2 × In for 60 s or 1.5 × In for 3 s under standard overload, and 1.5 × In for 60 s or 1.85 × In for 3 s under high overload. That means the drive can handle a 185 % current spike for three seconds — enough to start a loaded conveyor or crusher without tripping on the inrush. The prospective short-circuit current rating is 31.5 kA for 150 ms, which tells the site electrical engineer that the upstream protection (fuses or breaker) must be coordinated to clear within that window. The line current draw is 65 A at the rated operating point. Electrical connection is via M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, with entry from the top or bottom of the enclosure. That gives the panel builder flexibility in cable routing, but the lug size and bending radius need to be checked against the actual cable spec. ## Compliance and documentation for global projects The drive carries CE marking and is designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Lifecycle status is current production. The paperwork — CE declaration, IEC compliance statements — is available with the shipment.","metaTitle":"Schneider ATV1200A5606666 AC Drive, 468 kW, 560 kVA","metaDescription":"Schneider Electric ATV1200A5606666 Altivar 1200 medium-voltage drive, 468 kW, 560 kVA, 36-pulse input, CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"3360 mm (high efficiency) 3060 mm (standard efficiency)","title":"ATV1200A5606666","Height":"2520 mm standard efficiency 2670 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"36 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6.6 kV - 560 kVA","Line current":"65 A","Apparent power":"560 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"468 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 18 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"16500 m3/h (high efficiency) 13200 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP31 IP42","Network number of phases":"3 phases","Continuous output current":"49 A (standard overload) 39 A (high overload)","Maximum transient current":"59 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6.6 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Vector control with sensor, optional Voltage/frequency ratio (V/f) Closed-loop control with encoder Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"19 kW (standard efficiency) 16 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A5606666?filename=Schneider+Electric_Altivar-1200_ATV1200A5606666.pdf', 'path_name': '905a8d557196e600aeac863bd2ee842f.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/905a8d557196e600aeac863bd2ee842f.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A5606666/medium-voltage-variable-speed-drive-atv1200-6-6-kv-560-kva/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for ATV1200A5606666?","answer":"The drive is CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The CE declaration and IEC compliance statements are provided with the unit."},{"question":"How is ATV1200A5606666 quoted for volume purchases?","answer":"The drive is sourced to order against the BOM quantity through authorized distribution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A5606666","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A5606666 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}