{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A5703333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A5703333","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A5703333","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A5703333","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A5703333 medium-voltage AC drive, 570 kVA, 477 kW, 18-pulse rectifier, floor-standing enclosure.","salesMarkdown":"## Physical footprint and enclosure The ATV1200A5703333: This drive ships in a floor-standing enclosure with separate air flows for the power section and control compartment. The standard-efficiency variant measures 1400 mm deep by 2460 mm wide by 2520 mm high; the high-efficiency variant adds depth to 1500 mm, width to 2760 mm, and height to 2670 mm. Forced-convection cooling moves 9900 m³/h (standard efficiency) or 13200 m³/h (high efficiency) of air. The 80 dB noise level means the enclosure location needs an acoustic assessment if it sits near occupied areas. ## Power section and input topology The input stage uses an 18-pulse diode rectifier bridge, which reduces line-side harmonics below the limits of IEEE 519 without an external filter. Supply voltage limits are 2970 to 3630 V AC, drawing 100 A line current at full load. Apparent power rating is 570 kVA, with a motor power capability of 477 kW for both asynchronous and synchronous motors. Output voltage equals the supply voltage, so the motor winding insulation must match the incoming line level. The drive withstands a prospective short-circuit current of 31.5 kA for 150 ms — coordinate the upstream protection to clear within that window to avoid damage to the input bridge. ## Overload capability and motor protection Standard overload profile handles 1.2 × In for 60 seconds and 1.5 × In for 3 seconds. The high-overload profile extends to 1.5 × In for 60 seconds and 1.85 × In for 3 seconds — this matters when sizing for high-inertia loads like centrifuges or crushers that need breakaway torque. Ground-fault protection is built into the drive, covering the power section. Dielectric strength between earth and power terminals is 10 kV AC. ## Control wiring and auxiliaries The control section needs an external 220 V AC supply rated at 3 kVA; an optional 220 V AC/DC supply is available. The cooling fan runs on a separate 380 V AC supply, also optional. Electrical isolation between power and control circuits is standard. Four software-configurable analogue inputs (0–20 mA / 4–20 mA, 250 Ω impedance) and one analogue output of the same type handle process feedback. Six discrete inputs are standard, expandable to ten with an option card. The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3 (EMC), EN/IEC 61800-4, and EN/IEC 61800-5-1 (safety). Pollution degree 2 per the safety standard and overvoltage category II apply. An integrated EMC filter is fitted as standard. Operating altitude is 1000 to 2000 m with a derating of 0.6 % per 100 m above 1000 m — factor this into the installation if the site is above 1000 m elevation.","metaTitle":"Schneider Electric ATV1200A5703333 Altivar 1200 VFD, 570 kVA","metaDescription":"Schneider Electric ATV1200A5703333 medium-voltage VFD, 570 kVA apparent power, 477 kW motor rating, 18-pulse rectifier, CE marked. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"2460 mm (standard efficiency) 2760 mm (high efficiency)","title":"ATV1200A5703333","Height":"2520 mm standard efficiency 2670 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"18 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 3.3 kV - 570 kVA","Line current":"100 A","Apparent power":"570 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"477 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"10 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer 9 x power cells Medium voltage arrestors Cooling fans Human machine interface","Product destination":"Asynchronous motors Synchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"9900 m3/h (standard efficiency) 13200 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP41 IP31","Network number of phases":"3 phases","Continuous output current":"100 A (standard overload) 80 A (high overload)","Maximum transient current":"120 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"3.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Closed-loop control with encoder Vector control with sensor, optional Sensorless flux vector control Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"19 kW (standard efficiency) 17 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A5703333?filename=Schneider+Electric_Altivar-1200_ATV1200A5703333.pdf', 'path_name': '7050efa7b3fceb9471ab95ca6d753d9e.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/7050efa7b3fceb9471ab95ca6d753d9e.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A5703333/medium-voltage-variable-speed-drive-atv1200-3-3-kv-570-kva/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for ATV1200A5703333?","answer":"The drive is CE marked and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A5703333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A5703333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}