{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A62501010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A62501010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A62501010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A62501010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A62501010 medium-voltage AC drive, 5225 kW motor power, 6250 kVA apparent power, 48-pulse diode rectifier input, 2970-3630 V supply, floor-standing enclosure.","salesMarkdown":"## 5225 kW medium-voltage drive with 48-pulse input The ATV1200A62501010 is a Schneider Electric Altivar 1200 medium-voltage AC drive rated for 5225 kW motor power with 6250 kVA apparent power, designed for large asynchronous motor loads in industrial applications. The 48-pulse diode rectifier bridge input stage provides inherent harmonic mitigation, reducing line-side distortion without external filters — a key advantage for installations with strict power quality requirements. Supply voltage range is 2970 to 3630 V AC, placing this drive firmly in the medium-voltage class for applications where step-down transformers are impractical or undesirable. ## Overload capability and load profile matching The drive offers two overload profiles: standard overload at 1.2× In for 60 s or 1.5× In for 3 s, and high overload at 1.5× In for 60 s or 1.85× In for 3 s. The high-overload curve suits variable-torque loads like conveyors or extruders that need short-duration torque bursts. Line current draw is 410 A at rated conditions; the prospective short-circuit current withstand is 31.5 kA for 150 ms, which sets the SCCR coordination requirement for upstream protection. ## Physical footprint and cooling architecture The drive ships in a floor-standing enclosure with separate air flows for power and control sections. Dimensions are 3040 mm high, 9070 mm wide, and 1600 mm deep — this is a large, dedicated drive room installation, not a panel-mount unit. Forced convection cooling moves 56,400 m³/h of air at standard efficiency. The audible noise level is 80 dB — hearing protection is required in the drive room during operation. Operating altitude derating applies above 1000 m: 0.6 % current derating per 100 m up to 2000 m. Ambient relative humidity range is 0 to 90 % (0 to 95 % optional). ## Standards compliance and approvals The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1 applies. Dielectric strength is 28 kV AC between earth and power terminals. Electrical isolation between power and control circuits is maintained per standard. The product composition includes the plinth, phase-shifting transformer, medium-voltage arrestors, cooling fans, HMI, and 24 power cells. This is a complete drive system, not a bare chassis — the transformer and cell architecture are integral to the 48-pulse design.","metaTitle":"Schneider ATV1200A62501010 AC Drive, 5225 kW, 6250 kVA","metaDescription":"Schneider Electric ATV1200A62501010 medium-voltage AC drive, 5225 kW motor power, 6250 kVA apparent power, 48-pulse rectifier for harmonic mitigation. CE","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1600 mm (standard efficiency)","Width":"9070 mm (standard efficiency)","title":"ATV1200A62501010","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"48 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 10 kV - 6250 kVA","Line current":"410 A","Apparent power":"6250 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"5225 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"28 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 24 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"56400 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP31 IP42 IP41","Network number of phases":"3 phases","Continuous output current":"361 A (standard overload) 289 A (high overload)","Maximum transient current":"433 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"10 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Vector control with sensor, optional Closed-loop control with encoder Voltage/frequency ratio (V/f) Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"204 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A62501010?filename=Schneider+Electric_Altivar-1200_ATV1200A62501010.pdf', 'path_name': '70af6acec605057b2d7d6512cfa67c72.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/70af6acec605057b2d7d6512cfa67c72.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A62501010/medium-voltage-variable-speed-drive-atv1200-10-kv-6250-kva/"},"ai":{"faq":[{"question":"What is the ATV1200A62501010 used for?","answer":"This drive is designed for large asynchronous (induction) motors up to 5225 kW in medium-voltage applications. Typical uses include pumps, fans, conveyors, compressors, and extruders in heavy industrial settings where the 48-pulse rectifier reduces harmonic distortion on the supply network."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A62501010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A62501010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}